XDF 1.110000 DO NOT HAND EDIT!!!! (Trust me) %%HEADER%% 001000 FileVers ="2" 001005 DefTitle ="NVMG8" 001007 DescSize =0xF1 001006 Desc ="Covers 6DFC, 6DFD, 6DGC, 6DGD, Australian EL V8 5ltr ecu's from 1996-1998, and could cover more that Ive not yet tested. \r\nRequires 256k bin file, first 0x22000 to be 'padded' with null data. Not all parameters defined have been tested yet." 001010 Author ="Jaysen Anderson" 001030 BinSize =0x40000 001035 BaseOffset =0 001200 ADSAssoc ="" 001225 ADSCheck =0x0 001300 GenFlags =0x0 001325 ModeFlags =0x0 002000 Category0 ="Fuel" 002001 Category1 ="Spark" 002002 Category2 ="Sensors" 002003 Category3 ="Limits" 002004 Category4 ="Miscellaneous" 002005 Category5 ="Idle" 002006 Category6 ="Hardware" 002007 Category7 ="Scalers" 002008 Category8 ="Tests" 002009 Category9 ="Adaptive Learning" 002010 Category10 ="Failure Management" 002011 Category11 ="EGR" 002012 Category12 ="Purge" 002013 Category13 ="Accessories" 002014 Category14 ="Economy Mode" 002015 Category15 ="Transmission" 002016 Category16 ="Cruise Control" 002017 Category17 ="Transient Fuel" 002019 Category19 ="Unknown" %%END%% %%CONSTANT%% 000002 UniqueID =0x5938 000100 Cat0ID =0x9 020005 Title ="A/F Ratio for Goose Test" 020011 DescSize =0xB 020010 Desc ="V_KNK_FUEL" 020020 Units ="A/F Ratio" 020050 SizeInBits =0x10 020100 Address =0x2A3E8 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4B2D 000100 Cat0ID =0x9 020005 Title ="A/F Ratio for Self Test" 020011 DescSize =0x6 020010 Desc ="VRLAM" 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x2B490 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x38A7 000100 Cat0ID =0x9 020005 Title ="A/F Ratio Rich Limit" 020011 DescSize =0x44 020010 Desc ="REQV - Desired A/F ratio is clipped to this limit during self test." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x2B48C 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4D1 000100 Cat0ID =0x9 020005 Title ="A/F Ratio Lean Limit" 020011 DescSize =0x44 020010 Desc ="LEQV - Desired A/F ratio is clipped to this limit during self test." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x2B48E 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x114E 000100 Cat0ID =0x1 020005 Title ="Accel Enrichment Global Multiplier" 020011 DescSize =0xAD 020010 Desc ="AEM - A multiplier of the result of the 'Accel Enrichment Fuel' (aka FN1303) table lookup.\r\nMultiplier values less than 1 reduce fuel, values greater than 1 increase fuel." 020020 Units ="multiplier" 020100 Address =0x2A4F6 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1EA2 000100 Cat0ID =0x5 020005 Title ="Accel Enrichment Load Time Constant" 020011 DescSize =0xEA 020010 Desc ="TCAELD - The time constant for the rolling average calculation of the 'Accel Enrichment Load' (aka AELOAD) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x2ADD4 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x96E 000100 Cat0ID =0x1 020005 Title ="Accel Enrichment Minimum" 020011 DescSize =0x31 020010 Desc ="MINAE\r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2B0AA 020150 Flags =0x2 020200 Equation =X/262144,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x527F 000100 Cat0ID =0x1 020005 Title ="Accel Enrichment Min Delta Load" 020011 DescSize =0x51 020010 Desc ="AEACLD - The change in load required to indicate the intake manifold is filling." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x2A4FC 020150 Flags =0x3 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5544 000100 Cat0ID =0x1 020005 Title ="Accel Enrichment Min Throttle Rate" 020011 DescSize =0x67 020010 Desc ="AETAR - The rate of throttle change must be greater than this value to enable acceleration enrichment." 020020 Units ="deg/sec" 020100 Address =0x2A4FE 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2C34 000100 Cat0ID =0x11 020005 Title ="Acceleration Ramp Rate" 020011 DescSize =0x4F 020010 Desc ="ACLINC - The rate of acceleration from the current speed to the desired speed." 020020 Units ="mph/sec" 020050 SizeInBits =0x10 020100 Address =0x2A312 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x556F 000100 Cat0ID =0x1 020005 Title ="ACT Fraction for Accel Enrichment" 020011 DescSize =0x187 020010 Desc ="FRCTAE - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the input value to the 'Accel Enrichment Fuel Scaler for ACT to ECT' (aka FN020B) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0x2A4FF 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5BA0 000100 Cat0ID =0x2 020005 Title ="ACT Fraction for Base Dwell" 020011 DescSize =0x1CC 020010 Desc ="DWLWF - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the calculation of the estimated coil temperature value. This estimated value is checked against the 'Dwell Time Table Select Temperature' (aka DWLTMP) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0x2AA28 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5540 000100 Cat0ID =0x12 020005 Title ="ACT Fraction for Transient Fuel" 020011 DescSize =0x174 020010 Desc ="ALPHA - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the input value to the 'Fuel Scaler for ACT to ECT' (aka FN022) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0x2A4F4 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x35AA 000100 Cat0ID =0x1 020005 Title ="ACT Fraction for Fuel Base Table" 020011 DescSize =0x175 020010 Desc ="FRCBFT - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the input value to the 'Fuel Scaler for ACT to ECT' (aka FN022) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0x2B0B7 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5296 000100 Cat0ID =0x1 020005 Title ="ACT Fraction for Fuel Startup Table" 020011 DescSize =0x175 020010 Desc ="FRCSFT - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the input value to the 'Fuel Scaler for ACT to ECT' (aka FN022) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0x2B0B8 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7A52 000100 Cat0ID =0x1 020005 Title ="ACT Fraction for Spark" 020011 DescSize =0x35 020010 Desc ="FRCSPK - \r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="multiplier" 020100 Address =0x2AA0F 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6D2D 000100 Cat0ID =0x9 020005 Title ="ACT KOEO Max" 020011 DescSize =0x7 020010 Desc ="VIACT2" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A3DA 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3442 000100 Cat0ID =0x9 020005 Title ="ACT KOEO Min" 020011 DescSize =0x7 020010 Desc ="VIACT1" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A3D8 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x29F0 000100 Cat0ID =0x9 020005 Title ="ACT KOER Max" 020011 DescSize =0x7 020010 Desc ="VIACT4" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A3DE 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2C28 000100 Cat0ID =0x9 020005 Title ="ACT KOER Min" 020011 DescSize =0x7 020010 Desc ="VIACT3" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A3DC 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7563 000100 Cat0ID =0x4 020005 Title ="ACT Max" 020011 DescSize =0x53 020010 Desc ="ACTMAX - Value at which the eec considers that the sensor has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A33E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5153 000100 Cat0ID =0x4 020005 Title ="ACT Min" 020011 DescSize =0x54 020010 Desc ="ACTMIN - Value at which the eec considers that the sensor has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A33C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x362D 000100 Cat0ID =0x12 020005 Title ="Actual Intake Surface Fuel Multiplier" 020011 DescSize =0x61 020010 Desc ="AISFM - Multiplier of 'Actual_Intake_Surface_Fuel' (aka AISF) during deceleration fuel shut off." 020020 Units ="multiplier" 020100 Address =0x2B0C6 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4F4D 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Accel Enrichment Max" 020011 DescSize =0x69 020010 Desc ="AELIM - The maximum acceleration enrichment fuel flow permitted in order for adaptive learning to occur." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2B0F4 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x5 %%END%% %%CONSTANT%% 000002 UniqueID =0x61CC 000100 Cat0ID =0xA 020005 Title ="Adaptive Control ACT Max" 020011 DescSize =0x7 020010 Desc ="AFACT2" 020020 Units ="deg F" 020100 Address =0x2B0E9 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x619D 000100 Cat0ID =0xA 020005 Title ="Adaptive Control ACT Min" 020011 DescSize =0x7 020010 Desc ="AFACT1" 020020 Units ="deg F" 020100 Address =0x2B0E8 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4DA7 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Deadband" 020011 DescSize =0x335 020010 Desc ="DELAMB - This value is used to form the deadband around stoichiometric within which the adaptive learning loop counter values are not altered.\r\n\r\nWhen the HEGO is reporting a rich condition this parameter's value is added to the resultant value created by adding the HEGO Bias value to the stoichiometric A/F ratio to establish a lean A/F ratio which if greater than the lean 'Desired A/F Ratio' (aka LAMBSE) value being commanded then the loop counter incrementing does not occur.\r\n\r\nWhen the HEGO is reporting a lean condition this parameter's value is subtracted from the resultant value created by adding the HEGO Bias value to the stoichiometric A/F ratio to establish a rich A/F ratio which if less than the rich 'Desired A/F Ratio' (aka LAMBSE) value being commanded then loop counter incrementing does not occur." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x2B0EC 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2274 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Delay Time" 020011 DescSize =0xCD 020010 Desc ="ADAPTM - The time delay before adaptive learning is permitted once the ECT is between the values set by the 'Adaptive Control ECT Min' (aka AFECT1) and 'Adaptive Control ECT Max' (aka AFECT2) parameters." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x2B0EA 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2AF1 000100 Cat0ID =0xA 020005 Title ="Adaptive Control ECT Max" 020011 DescSize =0xBD 020010 Desc ="AFECT2 - Temperature at which the 'Adaptive Fuel Timer' (aka ADPTMR) is reset to zero.\r\n\r\nSee 'Adaptive Control Delay Time' (aka ADAPTM) for more information on how this parameter is used." 020020 Units ="deg F" 020100 Address =0x2B0E7 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3DA 000100 Cat0ID =0xA 020005 Title ="Adaptive Control ECT Min" 020011 DescSize =0xB8 020010 Desc ="AFECT1 - Temperature at which the 'Adaptive Fuel Timer' (aka ADPTMR) is started.\r\n\r\nSee 'Adaptive Control Delay Time' (aka ADAPTM) for more information on how this parameter is used." 020020 Units ="deg F" 020100 Address =0x2B0E6 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6265 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Fast HEGO Count" 020011 DescSize =0xE8 020010 Desc ="FAEGCT - The minimum number of HEGO counts required for adaptive learning to take place when the number of KAM warm ups is less than the 'Adaptive Control Max Warm Up Cycles' value. Lower values increase the adaptive learning rate." 020020 Units ="counts" 020100 Address =0x2B0FB 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x68D7 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Max" 020011 DescSize =0x39 020010 Desc ="MAXADP - The maximum value that KAMREF is allowed to be." 020020 Units ="multiplier" 020100 Address =0x2B0F3 020150 Flags =0x8 020200 Equation =(X/256)+0.5,TH|0|0|0|0| 020210 DecimalPl =0x3 020240 RangeHigh =128.0000 %%END%% %%CONSTANT%% 000002 UniqueID =0x6266 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Max Warm Up Cycles" 020011 DescSize =0x91 020010 Desc ="KWUCNT - The maximum number of warm up cycles to use the faster adaptive learning update rate. Beyond this value the normal update rate is used." 020020 Units ="no." 020100 Address =0x2B0FC 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4904 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Min" 020011 DescSize =0x39 020010 Desc ="MINADP - The minimum value that KAMREF is allowed to be." 020020 Units ="multiplier" 020100 Address =0x2B0F2 020150 Flags =0x8 020200 Equation =(X/256)+0.5,TH|0|0|0|0| 020210 DecimalPl =0x3 020240 RangeHigh =128.0000 %%END%% %%CONSTANT%% 000002 UniqueID =0x44DB 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Table Column Lockout" 020011 DescSize =0x124 020010 Desc ="DELCOL - If the difference between the current adaptive control learning table column (aka NRMCES) and the last adaptive control learning table column (aka LSTCOL) is greater than this value then adaptive learning is disabled. Used to reduce the effect of excessive transient changes in rpm." 020020 Units ="column" 020050 SizeInBits =0x10 020100 Address =0x2B0F0 020150 Flags =0x2 020200 Equation =X/256,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x40E3 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Table Row Lockout" 020011 DescSize =0x11F 020010 Desc ="DELROW - If the difference between the current adaptive control learning table row (aka NRMRLD) and the last adaptive control learning table row (aka LSTROW) is greater than this value then adaptive learning is disabled. Used to reduce the effect of excessive transient changes in load." 020020 Units ="row" 020050 SizeInBits =0x10 020100 Address =0x2B0EE 020150 Flags =0x2 020200 Equation =X/256,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x46B4 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Normal HEGO Count" 020011 DescSize =0xB9 020010 Desc ="ADEGCT - The minimum number of HEGO counts required for adaptive learning to take place when the number of KAM warm ups is greater than the 'Adaptive Control Max Warm Up Cycles' value." 020020 Units ="counts" 020100 Address =0x2B0FA 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x285A 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Transient Fuel Max" 020011 DescSize =0x6E 020010 Desc ="ADEFTR - The maximum transient fuel compensation fuel flow permitted in order for adaptive learning to occur." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2B0F8 020150 Flags =0x3 020200 Equation =X/65536,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x7EE9 000100 Cat0ID =0xE 020005 Title ="Adjustable Damper Min TP" 020011 DescSize =0x51 020010 Desc ="SHKTP - The minimum voltage above closed throttle to indicate hard acceleration." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x9412 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5599 000100 Cat0ID =0xB 020005 Title ="Airmass Flow Min For TP Calculation" 020011 DescSize =0xCE 020010 Desc ="IDLMAF - If the airmass is less than this then the eec sets the throttle value equal to the closed throttle value if either the TPS has failed, is less than 'TPS Max' value or greater than 'TPS Max' value." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2A97A 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x45FE 000100 Cat0ID =0xA 020005 Title ="Allow Adaptive Learning" 020011 DescSize =0xA8 020010 Desc ="Z_ADPSW - Set to \"4700\" to permit adaptive learning to occur, change to \"480F\" to disable adaptive learning.\r\n\r\nWARNING: Do not use any values other than one of these." 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x21B4 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x24BA 000100 Cat0ID =0x9 020005 Title ="AM2 Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT1 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A40A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5C4 000100 Cat0ID =0x9 020005 Title ="AM1 Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT2 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A40C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E0B 000100 Cat0ID =0x7 020005 Title ="Auxiliary Hardware Present" 020011 DescSize =0xD0 020010 Desc ="THRMHP - The four possible settings are;\r\n\r\n0 = None of the following hardware is present\r\n1 = Thermactor hardware present\r\n2 = Supercharger bypass valve present\r\n3 = Inlet manifold air control valve present" 020020 Units ="" 020100 Address =0x2B46F 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3492 000100 Cat0ID =0x9 020005 Title ="Battery Voltage Lower Limit" 020011 DescSize =0xA 020010 Desc ="VKYPWR - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A326 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6130 000100 Cat0ID =0x5 020005 Title ="Battery Voltage Time Constant" 020011 DescSize =0xE2 020010 Desc ="TCVBAT - The time constant for the rolling average calculation of the 'Battery Voltage' (aka VBAT) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x2ADD0 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6B6E 000100 Cat0ID =0x9 020005 Title ="BP Max During Test" 020011 DescSize =0x7 020010 Desc ="VBPDL2" 020020 Units ="clock ticks" 020050 SizeInBits =0x10 020100 Address =0x2A3EC 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xC47 000100 Cat0ID =0x9 020005 Title ="BP Max Time Between Update" 020011 DescSize =0x7 020010 Desc ="VBPMAX" 020020 Units ="secs" 020100 Address =0x2A3FE 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3AF5 000100 Cat0ID =0x9 020005 Title ="BP Min During Test" 020011 DescSize =0x7 020010 Desc ="VBPDL1" 020020 Units ="clock ticks" 020050 SizeInBits =0x10 020100 Address =0x2A3EA 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x60A6 000100 Cat0ID =0x3 020005 Title ="BP Time Constant" 020011 DescSize =0xF2 020010 Desc ="TCBBAR - The time constant for the rolling average calculation of the 'BP' (aka BP) and 'BP Average' (aka BAPBAR) values.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x2ADD6 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x530D 000100 Cat0ID =0x11 020005 Title ="Buttons Not Pressed Maximum" 020011 DescSize =0x60 020010 Desc ="HIHOLD - Highest value of Vehicle Speed Control Command Switch to indicate no button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E80 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x52E0 000100 Cat0ID =0x11 020005 Title ="Buttons Not Pressed Minimum" 020011 DescSize =0x5F 020010 Desc ="LOHOLD - Lowest value of Vehicle Speed Control Command Switch to indicate no button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E7E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xF37 000100 Cat0ID =0x6 020005 Title ="Buzz RPM" 020011 DescSize =0x53 020010 Desc ="BZZRPM - Additional rpm added to base target idle rpm at start up to clear engine." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2A542 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6BCB 000100 Cat0ID =0x6 020005 Title ="Buzz RPM Time" 020011 DescSize =0x7C 020010 Desc ="BZZTM - Duration that 'Buzz RPM' (aka BZZRPM) is added to base target idle rpm at startup. \r\n\r\nConversion to be determined." 020020 Units ="secs" 020100 Address =0x2A55B 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x56A5 000100 Cat0ID =0x1 020005 Title ="C/L Neutral Idle Fuel Max Time" 020011 DescSize =0xE9 020010 Desc ="NIOLD - If the 'Close Throttle Neutral Timer' (aka CTNTMR) exceeds this value then open loop mode is used when in neutral at idle. This value is only checked by the eec when at closed throttle. Set to '255' to disable this function." 020020 Units ="secs" 020100 Address =0x2A53C 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3E9E 000100 Cat0ID =0x9 020005 Title ="Canister Purge Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT5 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A412 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x13DF 000100 Cat0ID =0xD 020005 Title ="Canister Purge Min RPM" 020011 DescSize =0x44 020010 Desc ="EVRPM - \r\n\r\nDoes not appear to be used by the eec in this strategy." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2A946 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6A19 000100 Cat0ID =0xD 020005 Title ="Canister Purge Min RPM Hysteresis" 020011 DescSize =0x45 020010 Desc ="EVRPMH - \r\n\r\nDoes not appear to be used by the eec in this strategy." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2A948 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x131E 000100 Cat0ID =0x5 020005 Title ="Checksum" 020011 DescSize =0x9F 020010 Desc ="CHKSUM - Do not edit. This is recalculated automatically when the bin is saved. When emulating, upload this new checksum to the emulator after saving the bin." 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x2200A 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7F06 000100 Cat0ID =0xA 020005 Title ="Clear KAM" 020011 DescSize =0x1C6 020010 Desc ="Z_KAMCLR - Forces the re-initialisation of the Keep Alive Memory so that all adaptive learning information is cleared.\r\n\r\nNormally set to \"235D\", change this to \"2382\" to clear the KAM (either during running if your emulator permits 'on the fly' changes or by cycling the key to 'run' and then off) and then restore back to the original value. Does not affect the KAM during KOEO or KEOR tests.\r\n\r\nWARNING: Do not use any values other than one of these." 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x218C 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x52DB 000100 Cat0ID =0x11 020005 Title ="Coast Button Maximum" 020011 DescSize =0x5D 020010 Desc ="HCOAST - Highest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E74 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x52DA 000100 Cat0ID =0x11 020005 Title ="Coast Button Minimum" 020011 DescSize =0x5C 020010 Desc ="LCOAST - Lowest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E72 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x32B1 000100 Cat0ID =0x1 020005 Title ="Cold Engine Fuel Multiplier Update Time Limit" 020011 DescSize =0xEC 020010 Desc ="MULTM - When the 'Cold Engine Fuel Multiplier Update Timer' (aka MULTMR) exceeds this value then the 'Cold Engine Fuel Multiplier' (aka LAMMUL) value is updated.\r\n\r\nDoes not appear to be used in this ecu, possibly superseded by FN393F." 020020 Units ="secs" 020100 Address =0x2B0FD 020150 Flags =0x8 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 020240 RangeHigh =128.0000 %%END%% %%CONSTANT%% 000002 UniqueID =0x3367 000100 Cat0ID =0x5 020005 Title ="Cold Start Max ECT" 020011 DescSize =0x45 020010 Desc ="CTLOW - The maximum ECT for a cold start condition to be recognised." 020020 Units ="deg F" 020100 Address =0x2B467 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6082 000100 Cat0ID =0x5 020005 Title ="Cranking Mode Exit Min PIPs" 020011 DescSize =0xD7 020010 Desc ="NCNT - Once the ECT sensor has been read 8 times this is the minimum number of PIPs that must occur once the rpm is greater than the 'Cranking Mode Exit Min RPM' (aka NRUN) parameter in order to exit cranking mode." 020020 Units ="no." 020100 Address =0x2AD92 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5D9D 000100 Cat0ID =0x5 020005 Title ="Cranking Mode Exit RPM" 020011 DescSize =0xC2 020010 Desc ="NRUN - Once the ECT sensor has been read 8 times this is the minimum rpm required for the 'Cranking Mode Exit Min PIPs' (aka NCNT) parameter to be checked to see if cranking mode can be exited." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2AD98 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x128C 000100 Cat0ID =0x5 020005 Title ="Cranking Mode Re-enter RPM" 020011 DescSize =0x4E 020010 Desc ="NSTALL - If the rpm is less than this value then cranking mode is re-entered." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2AD9A 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x34AF 000100 Cat0ID =0x2 020005 Title ="Cranking Mode Spark" 020011 DescSize =0x137 020010 Desc ="Z_CRKSPK - The spark advance used during cranking. Adjust for highly modified engines that will not start with the stock advance value of 10 degrees.\r\n\r\nRequires the use of a \"black\" Computer Controlled Dwell (CCD) TFI module and the 'Computer Controlled Dwell Present' (aka CCDSW) parameter needs to be set.\r\n" 020020 Units ="deg adv" 020100 Address =0x55CA 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x56A6 000100 Cat0ID =0x1 020005 Title ="CT Neutral Timer Hysteresis" 020011 DescSize =0x84 020010 Desc ="NIHYS - Added to 'C/L Neutral Idle Fuel Max Time' to make the upper clip limit of the 'Closed Throttle Neutral Timer' (aka CTNTMR)." 020020 Units ="secs" 020100 Address =0x2A53D 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x583C 000100 Cat0ID =0x5 020005 Title ="CT Neutral Timer Max RPM" 020011 DescSize =0xF3 020010 Desc ="INLRPM - The base rpm added to the result of the 'CT Neutral Timer RPM Adder' (aka FN880) lookup. This resultant value is the maximum rpm allowed in order for the 'CT Neutral Timer' to count up and the 'CT Neutral Flag (aka CTNFLG) to be set." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2A92E 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7C1 000100 Cat0ID =0x5 020005 Title ="CT Neutral Timer Max RPM Hysteresis" 020011 DescSize =0x4B 020010 Desc ="INLRPH - Hysteresis for the 'CT Neutral Timer Max RPM' (aka INLRPM) value." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2A930 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5C04 000100 Cat0ID =0x2 020005 Title ="CT Tip In Flag Min Load" 020011 DescSize =0x56 020010 Desc ="TIPLOD - The minimum load in order for the closed throttle tip in flag to be cleared." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x2AA32 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x257B 000100 Cat0ID =0x2 020005 Title ="CT Tip In Flag Min Load Hysteresis" 020011 DescSize =0x3D 020010 Desc ="TIPHYS - Hysteresis for the 'CT Tip In Flag Min Load' value." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x2AA34 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2B9F 000100 Cat0ID =0x9 020005 Title ="CT to PT Transitions to Enable HEGO Switch Test" 020011 DescSize =0x7 020010 Desc ="VPTCNT" 020020 Units ="no." 020100 Address =0x2A37D 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5A6E 000100 Cat0ID =0x2 020005 Title ="CT Spark Adder" 020011 DescSize =0x30 020010 Desc ="KCS1 - Added to 'CT Spark vs RPM' lookup value." 020020 Units ="deg adv" 020050 SizeInBits =0x10 020100 Address =0x2A980 020150 Flags =0x3 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x35EF 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Desired AF Ratio" 020011 DescSize =0x7 020010 Desc ="VLAMCB" 020020 Units ="AF ratio" 020050 SizeInBits =0x10 020100 Address =0x2A370 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7D76 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Desired RPM" 020011 DescSize =0xA 020010 Desc ="VISCN1 - " 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2A372 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1CA8 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Injector Off Time" 020011 DescSize =0x7 020010 Desc ="VCBTM2" 020020 Units ="secs" 020100 Address =0x2A379 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3D8A 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Injector On Time" 020011 DescSize =0x7 020010 Desc ="VCBTM1" 020020 Units ="secs" 020100 Address =0x2A378 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4A03 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test RPM Drop" 020011 DescSize =0x7 020010 Desc ="VCBPCT" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x2A36E 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7730 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test RPM Drop Clip" 020011 DescSize =0x7 020010 Desc ="VCBCLP" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x2A36A 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1BC6 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test RPM Drop Increment" 020011 DescSize =0x7 020010 Desc ="VCBPAD" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x2A36C 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1B08 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test RPM Drop Time" 020011 DescSize =0x7 020010 Desc ="VISDL5" 020020 Units ="secs" 020100 Address =0x2A377 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x540 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Start Delay" 020011 DescSize =0x7 020010 Desc ="VCBDLY" 020020 Units ="secs" 020100 Address =0x2A374 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x377C 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Time Wait" 020011 DescSize =0x7 020010 Desc ="VISDL4" 020020 Units ="secs" 020100 Address =0x2A376 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x41FF 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Type" 020011 DescSize =0x54 020010 Desc ="VCBFLG -\r\n\r\n-1 = allow test\r\n 0 = inhibit test\r\n 1 = allow multiple entries to test" 020020 Units ="state" 020100 Address =0x2A375 020150 Flags =0x1 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5377 000100 Cat0ID =0x6 020005 Title ="Dashpot Min for Declutch" 020011 DescSize =0x12B 020010 Desc ="DASMIN - When at closed throttle this is the minimum dashpot (pre position airflow) allowed when the vehicle speed is greater than the resultant value created by adding the 'Dashpot Min MPH for Declutch' (aka DASMPH) and 'Dashpot Min MPH for Declutch Hysteresis' (aka DASMHYST) parameters together." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2A31E 020150 Flags =0x2 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x5375 000100 Cat0ID =0x6 020005 Title ="Dashpot Min MPH for Declutch" 020011 DescSize =0xD6 020010 Desc ="DASMPH - When the 'Dashpot Min for Declutch' (aka DASMIN) parameter is being used by the eec this is the minimum vehicle speed required for this minimum dashpot (pre position airflow) to be continue to be applied." 020020 Units ="mph" 020100 Address =0x2A31B 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5376 000100 Cat0ID =0x6 020005 Title ="Dashpot Min MPH for Declutch Hysteresis" 020011 DescSize =0x55 020010 Desc ="DASMHYST - Hysteresis for the 'Dashpot Min MPH for Declutch' (aka DASMPH) parameter." 020020 Units ="mph" 020100 Address =0x2A31C 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x563E 000100 Cat0ID =0x6 020005 Title ="Dashpot Offset" 020011 DescSize =0xA7 020010 Desc ="DASPTO - An offset added to the final dashpot (pre position airflow) value in order to ensure some airflow during tip in or tip out. Typically set around 0.10 lb/min." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2A528 020150 Flags =0x2 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x563F 000100 Cat0ID =0x6 020005 Title ="Dashpot TP" 020011 DescSize =0xCD 020010 Desc ="DELHYS - Used in the calculation of the dashpot (pre position airflow) value. Set equal to the sum of the following parameters;\r\n\r\n'TPS PT Threshold' (aka DELTA)\r\n'TPS PT Threshold Hysteresis' (aka HYSTS)" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A52A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x530E 000100 Cat0ID =0x11 020005 Title ="DC Correction Factor" 020011 DescSize =0x7 020010 Desc ="DCBIAS" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x8E82 020150 Flags =0x2 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x26B0 000100 Cat0ID =0x11 020005 Title ="Debounce Time Delay" 020011 DescSize =0x7 020010 Desc ="DEBTIM" 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x8E8A 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x51C8 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off CT Min Time Delay" 020011 DescSize =0x10A 020010 Desc ="CTDFSO - The minimum time delay required for deceleration fuel shut off to be permitted when the throttle is closed.\r\nSet to less than the 'Decel Fuel Shut Off Time Delay Extension' (aka CTEDSO) value.\r\nNot used if the 'Decel Fuel Shut Off PT Enable' switch is set." 020020 Units ="secs" 020100 Address =0x2B0D2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x788E 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Fuel Ramp Back Clip" 020011 DescSize =0x4B 020010 Desc ="DMIN - A clip applied to FN379.\r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="???" 020050 SizeInBits =0x10 020100 Address =0x2B0DC 020150 Flags =0x2 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3271 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Low Load Timer Run" 020011 DescSize =0x5B 020010 Desc ="DFLDL - The maximum load allowed for the 'Decel Fuel Shut Off Low Load Timer' to count up." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x2B0E0 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5DB7 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Low Load Timer Stop" 020011 DescSize =0x5D 020010 Desc ="DFLDH - The minimum load required for the 'Decel Fuel Shut Off Low Load Timer' to be reset." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x2B0E2 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x137B 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Low Load Time" 020011 DescSize =0xA 020010 Desc ="DLDFSO - " 020020 Units ="secs" 020100 Address =0x2B0E4 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4A83 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Max Load" 020011 DescSize =0x51 020010 Desc ="DFLOD - The maximum load allowed for deceleration fuel shut off to be permitted." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x2B0C8 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2FD3 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Max Load Hysteresis" 020011 DescSize =0x42 020010 Desc ="DFLODH - Hysteresis for the 'Decel Fuel Shut Off Max Load' value." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x2B0CA 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x73E5 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min ECT" 020011 DescSize =0x9F 020010 Desc ="DFSECT - The minimum ECT required for deceleration fuel shut off to be permitted prior to the 'Decel Fuel Shut Off Time Delay' (aka AGB) value being exceeded." 020020 Units ="deg F" 020100 Address =0x2B0C7 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6278 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min MPH" 020011 DescSize =0x5B 020010 Desc ="DFSVS - The minimum vehicle speed required for deceleration fuel shut off to be permitted." 020020 Units ="mph" 020100 Address =0x2B0DE 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x24A5 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min MPH Hysteresis" 020011 DescSize =0x4D 020010 Desc ="DFSVSH - Hysteresis for the 'Decel Fuel Shut Off Min MPH' (aka DFSVS) value." 020020 Units ="mph" 020100 Address =0x2B0DF 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x49D0 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min PIP To Remain O/L" 020011 DescSize =0x101 020010 Desc ="PIPNUM - After deceleration fuel shut off has finished this is the number of PIPs that must occur in order to stay in open loop mode. This prevents the desired AF ratio from ramping rich until the HEGO transport delay has passed. Set to 1 to calibrate out." 020020 Units ="pips" 020100 Address =0x2B0D5 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3E3A 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min RPM" 020011 DescSize =0x66 020010 Desc ="DFSRPM - The minimum rpm above the desired idle rpm at which deceleration fuel shut off is permitted." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2B0CC 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6056 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min RPM Hysteresis" 020011 DescSize =0x4E 020010 Desc ="DFSRPH - Hysteresis for the 'Decel Fuel Shut Off Min RPM' (aka DFSRPM) value." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2B0CE 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x8F5 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min Time at PT" 020011 DescSize =0xC4 020010 Desc ="DSFTM - The minimum time at part or wide open throttle required for deceleration fuel shut off to be permitted after the 'Decel Fuel Shut Off CT Min Time Delay' has occurred.\r\n\r\nNeeds confirming." 020020 Units ="secs" 020100 Address =0x2B0D4 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x10B 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Neutral Max Time" 020011 DescSize =0x9A 020010 Desc ="DSTM1 - The maximum time that deceleration fuel shut off is permitted during deceleration whilst in neutral.\r\nOnly used if 'Transmission Type' is 2 or 3." 020020 Units ="secs" 020100 Address =0x2B0D0 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x186C 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Shift Max Time" 020011 DescSize =0x75 020010 Desc ="DSTM2 - The maximum time that deceleration fuel shut off is permitted during gear shifts on manual gearbox vehicles." 020020 Units ="secs" 020100 Address =0x2B0D1 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x656 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Shift Min RPM" 020011 DescSize =0xAE 020010 Desc ="SHFRPM - The minimum rpm above the 'Desired Idle RPM' (aka DSDRPM) required for the deceleration fuel shut off to be permitted during gear shifts on manual gearbox vehicles." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2B0D8 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2F 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Shift Min RPM Hysteresis" 020011 DescSize =0x54 020010 Desc ="SHFHYS - Hysteresis for the 'Decel Fuel Shut Off Shift Min RPM' (aka SHFRPM) value." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2B0DA 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x3E60 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Shift Min TP Hysteresis" 020011 DescSize =0x34 020010 Desc ="TPHYS - \r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2B0D6 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x772 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Time Delay" 020011 DescSize =0xC4 020010 Desc ="AGB - The minimum time that must elapse after exiting crank in order for deceleration fuel shut off to be permitted when the ECT is less than the 'Decel Fuel Shut Off Min ECT' (aka DFSECT) value." 020020 Units ="secs" 020100 Address =0x2A4D7 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1D75 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Time Extension" 020011 DescSize =0x13E 020010 Desc ="CTEDSO - Used to keep deceleration fuel shut off continuing during long decelerations (such as lengthy descents) even if short tip in/tip out events occur.\r\nSet to greater than the 'Decel Fuel Shut Off CT Min Time Delay' (aka CTDFSO) value.\r\nNot used if the 'Decel Fuel Shut Off PT Enable' (aka PTDFSW) switch is set." 020020 Units ="secs" 020100 Address =0x2B0D3 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3998 000100 Cat0ID =0xB 020005 Title ="Default ACT" 020011 DescSize =0x6C 020010 Desc ="ACTFMM - Default value used for ACT when the ACT sensor has failed and (other conditions to be determined)." 020020 Units ="deg F" 020100 Address =0x2A975 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x182E 000100 Cat0ID =0x5 020005 Title ="Default BAP" 020011 DescSize =0x4E 020010 Desc ="KONBP - Default barometric pressure value used when no BAP sensor is fitted.." 020020 Units ="in Hg" 020100 Address =0x2AA4A 020200 Equation =X/8,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6F57 000100 Cat0ID =0xB 020005 Title ="Default BAP for Sensor Fail" 020011 DescSize =0x50 020010 Desc ="BAPFMM - Default barometric pressure value used when the BAP sensor has failed." 020020 Units ="in Hg" 020100 Address =0x2A97C 020200 Equation =X/8,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0xFE6 000100 Cat0ID =0xB 020005 Title ="Default ECT" 020011 DescSize =0x6C 020010 Desc ="ECTFMM - Default value used for ECT when the ECT sensor has failed and (other conditions to be determined)." 020020 Units ="deg F" 020100 Address =0x2A976 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x49DD 000100 Cat0ID =0xB 020005 Title ="Default Desired Idle RPM" 020011 DescSize =0x4E 020010 Desc ="FMMDSD - Default desired idle rpm when both TPS and MAF failed flags are set." 020020 Units ="rpm" 020100 Address =0x2A974 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5FF5 000100 Cat0ID =0xB 020005 Title ="Default ISC Dutycycle" 020011 DescSize =0x49 020010 Desc ="FMMISC - Default ISC dutycyle when both TPS and MAF failed flags are set" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x2A972 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1790 000100 Cat0ID =0xB 020005 Title ="Default TP" 020011 DescSize =0xA6 020010 Desc ="FMCTTP - Added to closed throttle value to give a default throttle value if either the TPS has failed, is less than 'TPS Min' value or greater than 'TPS Max' value." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A978 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xFE9 000100 Cat0ID =0x1 020005 Title ="Desired A/F Ratio Max" 020011 DescSize =0x59 020010 Desc ="LAMMAX - The desired A/F ratio is clipped to this limit during closed loop fuel control." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x2B0A6 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x809 000100 Cat0ID =0x1 020005 Title ="Desired A/F Ratio Min" 020011 DescSize =0x59 020010 Desc ="LAMMIN - The desired A/F ratio is clipped to this limit during closed loop fuel control." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x2B0A8 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5A85 000100 Cat0ID =0xC 020005 Title ="Desired EGR Valve Position Time Constant" 020011 DescSize =0xEF 020010 Desc ="TCDLOP - The time constant for the rolling average calculation of the 'Desired EGR Valve Position' (aka DELOPT) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x2ADC0 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x42DA 000100 Cat0ID =0x9 020005 Title ="Desired Idle RPM Self Test Time Constant" 020011 DescSize =0x18B 020010 Desc ="VTCDSN - The time constant for the rolling average calculation of the 'Desired Idle RPM' (aka DSDRPM) value during self test.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it.\r\n\r\nSetting to zero will result in the 'Desired Idle RPM Time Constant' (aka TCDESN) parameter being used in lieu of this parameter during self test." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x2A366 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xBA2 000100 Cat0ID =0x6 020005 Title ="Desired Idle RPM Time Constant" 020011 DescSize =0xE5 020010 Desc ="TCDESN - The time constant for the rolling average calculation of the 'Desired Idle RPM' (aka DSDRPM) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x2ADBE 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6D8E 000100 Cat0ID =0x1 020005 Title ="Desired Rich Correction" 020011 DescSize =0x81 020010 Desc ="LMBJMP - When exiting the Filtered Idle Airmass Region this value is subtracted from the desired AF ratio to richen the mixture." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x2B0F6 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7C3D 000100 Cat0ID =0x7 020005 Title ="Disable ISC" 020011 DescSize =0xE3 020010 Desc ="Z_ISCSW - Normally this is set to \"3A\", change to \"00\" to set the ISC valve dutycycle to 0% when determining the 'Throttle Body Air Flow' (aka ITHBMA) parameter value.\r\n\r\nWARNING: Do not use any values other than one of these." 020020 Units ="" 020100 Address =0x5E4D 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x197F 000100 Cat0ID =0x2 020005 Title ="Dwell Switch Point" 020011 DescSize =0x41 020010 Desc ="DWLTSW - Switch point for the change of maximum permitted dwell." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x2AA2A 020150 Flags =0x2 020200 Equation =X/65536,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7D4E 000100 Cat0ID =0x7 020005 Title ="Dwell Time Table Select Temperature" 020011 DescSize =0xD4 020010 Desc ="DWLTBP - The estimated coil temperature value used to determine which coil dwell time table is to be used. The tables are:\r\n\r\n'Dwell Time High Temperature' (aka FN160B)\r\n'Dwell Time Low Temperature' (aka FN160A)" 020020 Units ="deg F" 020100 Address =0x2AA29 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x30FD 000100 Cat0ID =0x2 020005 Title ="Dwell Turn On Time Low RPM Clip" 020011 DescSize =0x7 020010 Desc ="MINDLA" 020020 Units ="% of PIP period" 020050 SizeInBits =0x10 020100 Address =0x2AA24 020150 Flags =0x2 020200 Equation =X/655.36,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7F70 000100 Cat0ID =0x2 020005 Title ="Dwell Turn On Time High RPM Clip" 020011 DescSize =0x7 020010 Desc ="MINDLB" 020020 Units ="% of PIP period" 020050 SizeInBits =0x10 020100 Address =0x2AA26 020150 Flags =0x2 020200 Equation =X/655.36,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1379 000100 Cat0ID =0x9 020005 Title ="ECT KOEO Max" 020011 DescSize =0x7 020010 Desc ="VIECT2" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A3E2 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5622 000100 Cat0ID =0x9 020005 Title ="ECT KOEO Min" 020011 DescSize =0x7 020010 Desc ="VIECT1" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A3E0 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3FEB 000100 Cat0ID =0x9 020005 Title ="ECT KOER Max" 020011 DescSize =0x7 020010 Desc ="VIECT4" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F56 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x20B8 000100 Cat0ID =0x9 020005 Title ="ECT KOER Min" 020011 DescSize =0x7 020010 Desc ="VIECT3" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F54 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5DC4 000100 Cat0ID =0x4 020005 Title ="ECT Max" 020011 DescSize =0x54 020010 Desc ="ECTMAX - Value at which the eec considers that the sensor has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A354 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x356A 000100 Cat0ID =0xA 020005 Title ="ECT Max at Start for Warm Up Flag" 020011 DescSize =0xC9 020010 Desc ="VECT5 - The maximum coolant temperature at start up permitted for the KAM Warm Up counter to be updated. The temperature then needs to increase beyond the 'ECT Min for Warm Up Flag' (aka VECT3) value." 020020 Units ="deg F" 020100 Address =0x2A340 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x32F9 000100 Cat0ID =0x4 020005 Title ="ECT Min" 020011 DescSize =0x54 020010 Desc ="ECTMIN - Value at which the eec considers that the sensor has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A352 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6FE2 000100 Cat0ID =0xA 020005 Title ="ECT Min for Warm Up Flag" 020011 DescSize =0xCB 020010 Desc ="VECT3 - The minimum coolant temperature required for the KAM Warm Up counter to be updated. The temperature at start also needs to be less than the 'ECT Max at Start for Warm Up Flag' (aka VECT5) value." 020020 Units ="deg F" 020100 Address =0x2A3E6 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E9B 000100 Cat0ID =0x3 020005 Title ="ECT Time Constant" 020011 DescSize =0xD4 020010 Desc ="TCECT - The time constant for the rolling average calculation of the 'ECT' (aka ECT) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x2ADC4 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5DA2 000100 Cat0ID =0x7 020005 Title ="Engine Displacement" 020011 DescSize =0xA1 020010 Desc ="SARCHG - If altered the following parameters will need adjustment too;\r\n\r\n'Manifold Fast Fill Constant' (aka FKARC1)\r\n'Manifold Slow Fill Constant' (aka FKARCH)" 020020 Units ="Cubic In." 020050 SizeInBits =0x10 020100 Address =0x2A50E 020150 Flags =0x2 020200 Equation =X*0.0430981,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x568F 000100 Cat0ID =0x5 020005 Title ="Engine Warm ECT" 020011 DescSize =0x4F 020010 Desc ="TEMPFB - The minimum temperature at which the engine is considered to be warm." 020020 Units ="deg F" 020100 Address =0x2B468 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2505 000100 Cat0ID =0xC 020005 Title ="EPT at Idle Back Pressure" 020011 DescSize =0x62 020010 Desc ="IDLDEL - Checked during the key on 'EPT at Idle' (aka EPTZER) update routine.\r\n\r\nTo be confirmed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2AA4C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E37 000100 Cat0ID =0xC 020005 Title ="EPT at Idle Min ECT" 020011 DescSize =0x53 020010 Desc ="CTEHI - The minimum ECT for the 'EPT at Idle' (aka EPTZER) value to be calculated." 020020 Units ="deg F" 020100 Address =0x2ADB4 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x34BC 000100 Cat0ID =0xC 020005 Title ="EPT at Idle RPM Hysteresis" 020011 DescSize =0x94 020010 Desc ="IERPMH - Hysteresis value added to 'Desired Idle RPM' value. If the rpm exceeds this resultant value then the 'EPT at Idle' calculation is skipped." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2ADB2 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4EC4 000100 Cat0ID =0x9 020005 Title ="EPT Continuous Test Max" 020011 DescSize =0x7 020010 Desc ="VEPTIH" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F9C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x198C 000100 Cat0ID =0x9 020005 Title ="EPT Continuous Test Min" 020011 DescSize =0x7 020010 Desc ="VEPTIL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F9A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x773F 000100 Cat0ID =0x9 020005 Title ="EPT Cruise Test Min" 020011 DescSize =0x7 020010 Desc ="VEPTCL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8FA0 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4514 000100 Cat0ID =0x9 020005 Title ="EPT KOEO Max" 020011 DescSize =0x7 020010 Desc ="VEPTHL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F94 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1B88 000100 Cat0ID =0x9 020005 Title ="EPT KOEO Min" 020011 DescSize =0x7 020010 Desc ="VEPTLL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F92 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x592F 000100 Cat0ID =0x9 020005 Title ="EPT KOER Max" 020011 DescSize =0x7 020010 Desc ="VEPTRH" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F98 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5B53 000100 Cat0ID =0x9 020005 Title ="EPT KOER Min" 020011 DescSize =0x7 020010 Desc ="VEPTRL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F96 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6A24 000100 Cat0ID =0x9 020005 Title ="EPT KOER Min Change" 020011 DescSize =0x7 020010 Desc ="VEPTDL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F9E 020150 Flags =0x3 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7952 000100 Cat0ID =0x4 020005 Title ="EPT Max" 020011 DescSize =0x69 020010 Desc ="EPTMAX - Value at which the eec considers that the exhaust pressure transducer has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F90 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4FA4 000100 Cat0ID =0x4 020005 Title ="EPT Min" 020011 DescSize =0x69 020010 Desc ="EPTMIN - Value at which the eec considers that the exhaust pressure transducer has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F8E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x59C8 000100 Cat0ID =0x9 020005 Title ="EPT Test Time Constant" 020011 DescSize =0xE9 020010 Desc ="VTCEPT - The time constant for the rolling average calculation of the 'EPT' (aka EPTBAR) value during self test.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x8FA4 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xF53 000100 Cat0ID =0xC 020005 Title ="EPT Time Constant" 020011 DescSize =0xF7 020010 Desc ="TCEPT - The time constant for the rolling average calculation of the 'EPT' (aka EPTBAR) and 'EPT at Idle' (aka EPTZER) values.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97F0 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E03 000100 Cat0ID =0xC 020005 Title ="EPT Transfer" 020011 DescSize =0x7 020010 Desc ="XFREPT" 020020 Units ="in H2O/counts" 020050 SizeInBits =0x10 020100 Address =0x97D4 020150 Flags =0x3 020200 Equation =X/131072,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xBA1 000100 Cat0ID =0xC 020005 Title ="EPT Transfer Reciprocol" 020011 DescSize =0x7 020010 Desc ="IXFRPR" 020020 Units ="counts/in H2O" 020050 SizeInBits =0x10 020100 Address =0x97D6 020150 Flags =0x3 020200 Equation =X/131072,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5574 000100 Cat0ID =0x12 020005 Title ="Equilibrium Fuel Transfer Constant Multiplier" 020011 DescSize =0x6B 020010 Desc ="MTEFTC - A multiplier of the result of the 'Equilibrium Fuel Transfer Constant' (aka FN1322) table lookup." 020020 Units ="multiplier" 020100 Address =0x2A506 020200 Equation =X/32,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5573 000100 Cat0ID =0x12 020005 Title ="Equilibrium Intake Surface Fuel Multiplier" 020011 DescSize =0x68 020010 Desc ="MTEISF - A multiplier of the result of the 'Equilibrium Intake Surface Fuel' (aka FN1321) table lookup." 020020 Units ="multiplier" 020100 Address =0x2A505 020200 Equation =X/32,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6A18 000100 Cat0ID =0x9 020005 Title ="Failure Mode Hysteresis" 020011 DescSize =0x50 020010 Desc ="FILHYS - Hysteresis value for the 'Error ** Threshold' (aka C**LVL) parameters." 020020 Units ="" 020100 Address =0x2A3E7 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x69F6 000100 Cat0ID =0x6 020005 Title ="FAM Deadband" 020011 DescSize =0x7 020010 Desc ="FAMLIM" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x2A548 020150 Flags =0x2 020200 Equation =X/655.36,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5E9C 000100 Cat0ID =0x6 020005 Title ="FAM Entry Airmass Maximum" 020011 DescSize =0x69 020010 Desc ="TCFAM - The maximum airmass in order for the FAM_FLG to be set.\r\n\r\nPID to be confirmed (probably wrong)" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2ADCA 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x133F 000100 Cat0ID =0x6 020005 Title ="FAM Entry Max Multiplier" 020011 DescSize =0xA6 020010 Desc ="EFAMPH - On entry to the filtered air mass region the filtered air mass value is multiplied by this parameter to establish an upper clip limit on the air mass value." 020020 Units ="multiplier" 020100 Address =0x2B485 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x63C9 000100 Cat0ID =0x6 020005 Title ="FAM Entry Min Multiplier" 020011 DescSize =0xA6 020010 Desc ="EFAMPL - On entry to the filtered air mass region the filtered air mass value is multiplied by this parameter to establish an lower clip limit on the air mass value." 020020 Units ="multiplier" 020100 Address =0x2B486 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5673 000100 Cat0ID =0x6 020005 Title ="FAM Filter Sample Rate" 020011 DescSize =0x6B 020010 Desc ="SAMRAT - Used to pace the filter rate for the filtered airmass in terms of program background loop counts." 020020 Units ="background counts" 020100 Address =0x2A536 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6399 000100 Cat0ID =0x6 020005 Title ="FAM Incremental Adder" 020011 DescSize =0x61 020010 Desc ="AMRPM - Added to desird idle rpm to give a maximum rpm below which air mass filtering can occur." 020020 Units ="rpm" 020100 Address =0x2B483 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5238 000100 Cat0ID =0x6 020005 Title ="FAM Incremental Adder Hysteresis" 020011 DescSize =0x40 020010 Desc ="AMRPMH - Hysteresis for the 'FAM Incremental Adder' parameter." 020020 Units ="rpm" 020100 Address =0x2B484 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x55DB 000100 Cat0ID =0x6 020005 Title ="FAM Increment/Decrement" 020011 DescSize =0x7 020010 Desc ="FAMINC" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2A514 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x56DC 000100 Cat0ID =0x6 020005 Title ="FAM Maximum Clip Multiplier" 020011 DescSize =0x8A 020010 Desc ="MAXFAM - The instantaneous air mass value is multiplied by this parameter to establish an upper clip limit on the filtered airmass value." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0x2A54A 020150 Flags =0x2 020200 Equation =X/32768,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6398 000100 Cat0ID =0x6 020005 Title ="FAM Max RPM" 020011 DescSize =0x52 020010 Desc ="AMDESN - The maximum desired idle rpm at which air mass filtering can be enabled." 020020 Units ="rpm" 020100 Address =0x2B482 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6366 000100 Cat0ID =0x6 020005 Title ="FAM Multiplier" 020011 DescSize =0xD4 020010 Desc ="DELTAM - A multiplier of the filtered airmass value that establishes a value that when exceeded by the instantaneous airmass causes the eec to use the instantaneous airmass in lieu of the filtered airmass value." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0x2B480 020150 Flags =0x2 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5672 000100 Cat0ID =0x6 020005 Title ="FAM TP" 020011 DescSize =0x12A 020010 Desc ="DELRAT - When the relative throttle position is less than or equal to this parameter then FAM entry is allowed providing the other conditions for FAM entry are satisfied. Set equal to the sum of the following parameters;\r\n\r\n'TPS PT Threshold' (aka DELTA)\r\n'TPS PT Threshold Hysteresis' (aka HYSTS)" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A534 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x721F 000100 Cat0ID =0x6 020005 Title ="FAM TP Hysteresis" 020011 DescSize =0x7 020010 Desc ="DLHYST" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2B488 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x49C8 000100 Cat0ID =0x5 020005 Title ="Force Continuous O/L" 020011 DescSize =0xEC 020010 Desc ="Z_OLSW - Normally this is set to \"D7\", change to \"20\" to prevent the ecu going into closed loop mode.\r\n\r\nWARNING: Do not enter any value other than one of these.\r\n\r\nThis needs verifying that CL is forced under all operating conditions." 020020 Units ="n/a" 020100 Address =0x4274 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6244 000100 Cat0ID =0x7 020005 Title ="Fixed Injector Timing Cold Start Delay #1" 020011 DescSize =0x129 020010 Desc ="NITMR1 - When the ECT at start is less than the 'Cold Start Max ECT' value this is the minimum time that must pass since exiting crank in order for it to be possible to use fixed injector timing when in neutral.\r\n\r\nNote: the 'Fixed Injector Timing Cold Start Delay #2' value also needs exceeding." 020020 Units ="secs" 020100 Address =0x2B0C4 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5B7C 000100 Cat0ID =0x7 020005 Title ="Fixed Injector Timing Cold Start Delay #2" 020011 DescSize =0x147 020010 Desc ="NITMR4 - When the ECTat start is less than the 'Cold Start Max ECT' value this is the minimum time that must pass since the ECT exceeded the 'Engine Warm ECT' value in order for it to be possible to use fixed injector timing when in neutral.\r\n\r\nNote: the 'Fixed Injector Timing Cold Start Delay #1' value also needs exceeding." 020020 Units ="secs" 020100 Address =0x2B0C5 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4A8B 000100 Cat0ID =0x7 020005 Title ="Fixed Injector Timing Hot Start Delay" 020011 DescSize =0xD6 020010 Desc ="NITMR3 - When the ECT at start is greater than the 'Hot Start Min ECT' value this is the minimum time that must pass since exiting crank in order for it to be possible to use fixed injector timing when in neutral." 020020 Units ="secs" 020100 Address =0x2B0C1 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xE01 000100 Cat0ID =0x7 020005 Title ="Fixed Injector Timing Warm Start Delay #1" 020011 DescSize =0x140 020010 Desc ="NITMR2 - When the ECT at start is between the 'Cold Start Max ECT' and 'Hot Start Min ECT' values this is the minimum time that must pass since exiting crank in order for it to be possible to use fixed injector timing when in neutral.\r\n\r\nNote: the 'Fixed Injector Timing Warm Start Delay #2' value also needs exceeding." 020020 Units ="secs" 020100 Address =0x2B0C2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x706D 000100 Cat0ID =0x7 020005 Title ="Fixed Injector Timing Warm Start Delay #2" 020011 DescSize =0x15F 020010 Desc ="NITMR5 - When the ECT at start is between the 'Cold Start Max ECT' and 'Hot Start Min ECT' values this is the minimum time that must pass since the ECT exceeded the 'Engine Warm ECT' value in order for it to be possible to use fixed injector timing when in neutral.\r\n\r\nNote: the 'Fixed Injector Timing Warm Start Delay #1' value also needs exceeding." 020020 Units ="secs" 020100 Address =0x2B0C3 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x58D6 000100 Cat0ID =0x1 020005 Title ="Fuel Lugging Mode O/L Max ECT" 020011 DescSize =0x5 020010 Desc ="LDEH" 020020 Units ="deg F" 020100 Address =0x2AD89 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7778 000100 Cat0ID =0x1 020005 Title ="Fuel Lugging Mode O/L Min ECT" 020011 DescSize =0x5 020010 Desc ="LDEL" 020020 Units ="deg F" 020100 Address =0x2AD88 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5348 000100 Cat0ID =0x1 020005 Title ="Fuel Lugging Mode O/L Min Load%" 020011 DescSize =0xFF 020010 Desc ="LDMH - When LOAD% is greater or equal to the sum of this value plus the 'Fuel Lugging Mode O/L Min Load% Hysteresis' (aka LDMHH) parameter value then one of the conditions required for the setting of the 'Lugging O/L Flag' (aka LDFLG) will have been met." 020020 Units ="load%" 020050 SizeInBits =0x10 020100 Address =0x2AD8C 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x83A 000100 Cat0ID =0x1 020005 Title ="Fuel Lugging Mode O/L Min Load% Hysteresis" 020011 DescSize =0x59 020010 Desc ="LDMHH - Hysteresis value for the 'Fuel Lugging Mode O/L Min Load%' (aka LDMH) parameter." 020020 Units ="load%" 020050 SizeInBits =0x10 020100 Address =0x2AD8E 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x392C 000100 Cat0ID =0x1 020005 Title ="Fuel Global Multiplier" 020011 DescSize =0xAB 020010 Desc ="OLMCL - A global multiplier that adjusts the desired A/F ratio when in open loop mode. \r\n\r\nMultiplier values less than 1 increase fuel, values greater than 1 reduce fuel." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0x2AD90 020150 Flags =0x2 020200 Equation =X/256,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x64D9 000100 Cat0ID =0x9 020005 Title ="Fuel Pump Monitor KOEO Test Delay" 020011 DescSize =0x9 020010 Desc ="V_FPMDLY" 020020 Units ="secs" 020100 Address =0x2A348 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x504D 000100 Cat0ID =0x9 020005 Title ="Fuel Pump Monitor Test Delay" 020011 DescSize =0x8 020010 Desc ="V_FPMTM" 020020 Units ="secs" 020100 Address =0x2A349 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x291E 000100 Cat0ID =0x9 020005 Title ="Fuel Pump Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT7 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A414 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3A22 000100 Cat0ID =0x9 020005 Title ="Fuel Test Exit Delay" 020011 DescSize =0x9 020010 Desc ="VDLY8 - " 020020 Units ="secs" 020100 Address =0x2A32E 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3A12 000100 Cat0ID =0x9 020005 Title ="Goose Idle Delay Time" 020011 DescSize =0x7 020010 Desc ="VISDL3" 020020 Units ="secs" 020100 Address =0x2B49A 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7FA1 000100 Cat0ID =0x9 020005 Title ="Goose Idle RPM" 020011 DescSize =0x7 020010 Desc ="ISLBND" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2B49C 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x3DD 000100 Cat0ID =0x9 020005 Title ="Goose Minimum MAP Change" 020011 DescSize =0x4D 020010 Desc ="V_GOOSMP -The minimum MAP change to determine goose test has been undetaken." 020020 Units ="in Hg" 020100 Address =0x2A35B 020200 Equation =X/8,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x749 000100 Cat0ID =0x9 020005 Title ="Goose Minimum RPM Change" 020011 DescSize =0x4C 020010 Desc ="V_GOOSN -The minimum rpm change to determine goose test has been undetaken." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2A35C 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x472F 000100 Cat0ID =0x9 020005 Title ="Goose Minimum TP Change" 020011 DescSize =0x53 020010 Desc ="V_GOOSTP - The minimum throttle change to determine goose test has been undetaken." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x2A360 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x236A 000100 Cat0ID =0x9 020005 Title ="Goose Spark" 020011 DescSize =0x9 020010 Desc ="V_GOOSPK" 020020 Units ="degrees" 020050 SizeInBits =0x10 020100 Address =0x2A35E 020150 Flags =0x3 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0xB1F 000100 Cat0ID =0x9 020005 Title ="Goose Test Desired RPM" 020011 DescSize =0x9 020010 Desc ="NGOOSE -" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2B49E 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x68F1 000100 Cat0ID =0x9 020005 Title ="Goose Test Time" 020011 DescSize =0x75 020010 Desc ="V_GOOSEC - The maximum time allowed for the the operator to respond to the request for the throttle to be 'goosed'." 020020 Units ="secs" 020100 Address =0x2A35A 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1EF0 000100 Cat0ID =0x9 020005 Title ="HEGO Average Test Time Constant" 020011 DescSize =0xF2 020010 Desc ="VTCEGO - The time constant for the rolling average calculation of the 'HEGO Average' (aka EGOBAR) value during self test.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x2A358 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3E39 000100 Cat0ID =0x5 020005 Title ="HEGO Min Switches Before Warm" 020011 DescSize =0x99 020010 Desc ="EGOCL1 - The number of HEGO switches required for the WARM_EGO_FLAG to be set providing the appropriate 'Warm HEGO Flag ....' delay times have been met." 020020 Units ="no." 020100 Address =0x2B09C 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x583E 000100 Cat0ID =0xB 020005 Title ="HEGO Switch Time Delay" 020011 DescSize =0x8A 020010 Desc ="BYPLES - When the time since the last HEGO switch occurred exceeds this value then the 'Lack of HEGO Switching Flag' (aka LEGOFG) is set." 020020 Units ="secs" 020100 Address =0x2A932 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4467 000100 Cat0ID =0x9 020005 Title ="HEGO Test Lean Time Wait" 020011 DescSize =0x7 020010 Desc ="VIPTM3" 020020 Units ="secs" 020100 Address =0x2B492 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x457B 000100 Cat0ID =0x9 020005 Title ="HEGO Test Min RPM" 020011 DescSize =0x6 020010 Desc ="VNMIN" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2A32C 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0xF6F 000100 Cat0ID =0x9 020005 Title ="HEGO Test Min Time at C/L ECT" 020011 DescSize =0x92 020010 Desc ="VEGOTM - The minimum time after the minimum coolant temperature for closed loop operation has been reached before the HEGO test can be performed." 020020 Units ="secs" 020100 Address =0x2A37C 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x651F 000100 Cat0ID =0x9 020005 Title ="HEGO Test Rich Time Wait" 020011 DescSize =0x7 020010 Desc ="VIPTM4" 020020 Units ="secs" 020100 Address =0x2A97D 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7EAA 000100 Cat0ID =0x9 020005 Title ="HEGO Test Switch Time Delay" 020011 DescSize =0x7 020010 Desc ="VIPTM2" 020020 Units ="secs" 020100 Address =0x2A440 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7229 000100 Cat0ID =0x5 020005 Title ="Hot Start Min ECT" 020011 DescSize =0xC2 020010 Desc ="CTHIGH - The minimum ECT for a hot start condition to be recognised.\r\n\r\nThis is also the minimum ECT in order for the 'CT Neutral Timer' (aka CTNTMR) to count up (other conditions permitting). " 020020 Units ="deg F" 020100 Address =0x2B466 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x570B 000100 Cat0ID =0x6 020005 Title ="Idle Airflow Decrement for A/C" 020011 DescSize =0x6F 020010 Desc ="DACPPM - The reduction in predicted idle airflow through the ISC valve required when the aircon is turned off." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2A552 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x570A 000100 Cat0ID =0x6 020005 Title ="Idle Airflow Increment for A/C" 020011 DescSize =0x6C 020010 Desc ="ACPPM - The increase in predicted idle airflow through the ISC valve required when the aircon is turned on." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2A550 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5774 000100 Cat0ID =0x6 020005 Title ="Idle Airflow Increment for Heated Windcreen" 020011 DescSize =0x77 020010 Desc ="HWPPM - The increase in predicted idle airflow through the ISC valve required when the heated windscreen is turned on." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2A908 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x570C 000100 Cat0ID =0x6 020005 Title ="Idle Airflow Increment for Power Steering" 020011 DescSize =0x8A 020010 Desc ="PSPPM - The increase in predicted idle airflow through the ISC valve required when the power steering places addition load on the engine." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2A554 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x693D 000100 Cat0ID =0x6 020005 Title ="Idle GPAS Clip Limit" 020011 DescSize =0x5A 020010 Desc ="ISCLPD - If the base target idle speed values have been altered then adjust this to suit." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2A546 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x43E5 000100 Cat0ID =0x6 020005 Title ="Idle GPAS Minimum Time" 020011 DescSize =0x80 020010 Desc ="CRKTIM - The minimum time in run mode that must be exceeded in order for the 'Idle GPAS Clip Limit' (aka ISCLPD) to be invoked." 020020 Units ="secs" 020100 Address =0x2AD9C 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x62ED 000100 Cat0ID =0x6 020005 Title ="Idle RPM Adder for A/C" 020011 DescSize =0x89 020010 Desc ="DNAC - Adds rpm to 'Desired Idle RPM' when aircon clutch is engaged, used to compensate for the additional load the compressor imposes." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2A544 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x890 000100 Cat0ID =0x6 020005 Title ="Idle RPM Adder for A/C Time" 020011 DescSize =0x54 020010 Desc ="DACTM - Time to maintain idle aircon rpm adder after aircon clutch has disengaged." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x2A556 020150 Flags =0x2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x51A2 000100 Cat0ID =0x6 020005 Title ="Idle RPM Adder for Power Steering" 020011 DescSize =0x82 020010 Desc ="DNPOWS - Adds rpm to 'Desired Idle RPM' when power steering is engaged, used to compensate for the additional load this imposes." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2A558 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x40BB 000100 Cat0ID =0x6 020005 Title ="Idle RPM for Heated Windscreen" 020011 DescSize =0x59 020010 Desc ="HWRPM - Minimum idle rpm in neutral when the heated windscreen is on for the first time." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8C04 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2D91 000100 Cat0ID =0x6 020005 Title ="Idle Speed Drive" 020011 DescSize =0xE6 020010 Desc ="DRBASE - Base target idle speed in drive before adders. If altered, adjust the 'Max RPM for Idle Flag' (aka IDLRPM) parameter too. The 'ISC Gain vs RPM Error' (aka FN824) parameter might also need adjusting too (to be confirmed)." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2A540 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5583 000100 Cat0ID =0x6 020005 Title ="Idle Speed Neutral" 020011 DescSize =0xE8 020010 Desc ="NUBASE - Base target idle speed in neutral before adders. If altered, adjust the 'Max RPM for Idle Flag' (aka IDLRPM) parameter too. The 'ISC Gain vs RPM Error' (aka FN824) parameter might also need adjusting too (to be confirmed)." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2A53E 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x22BB 000100 Cat0ID =0x6 020005 Title ="Idle Startup Adder Time" 020011 DescSize =0x6E 020010 Desc ="TKDTM - Time since exiting crank when 'ISC Startup Adder' (aka FN826A) is used as a 'Desired Idle RPM' adder." 020020 Units ="secs" 020100 Address =0x2A55A 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5CD6 000100 Cat0ID =0x9 020005 Title ="IDM Error Threshold" 020011 DescSize =0xA 020010 Desc ="IDMLVL - " 020020 Units ="" 020100 Address =0x8F30 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1119 000100 Cat0ID =0x9 020005 Title ="IDM Error Upcount" 020011 DescSize =0x9 020010 Desc ="IDMUP - " 020020 Units ="" 020100 Address =0x8F46 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x529 000100 Cat0ID =0x7 020005 Title ="Ignition Degrees Per PIP" 020011 DescSize =0x6B 020010 Desc ="DEGPIP - The number of crank degrees per PIP interval. 90 = 8 cylinder, 120 = 6 cylinder, 180 = 4 cylinder" 020020 Units ="degrees" 020050 SizeInBits =0x10 020100 Address =0x2B0AE 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x63CB 000100 Cat0ID =0x1 020005 Title ="Initial FAM" 020011 DescSize =0x5 020010 Desc ="IFAM" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2B48A 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x4661 000100 Cat0ID =0xB 020005 Title ="Initial TP" 020011 DescSize =0x8A 020010 Desc ="RATIV - Closed throttle value used by the eec if either the TPS has failed, is less than 'TPS Max' value or greater than 'TPS Max' value." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8C02 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x46A1 000100 Cat0ID =0x7 020005 Title ="Injector Fire Method" 020011 DescSize =0x2A 020010 Desc ="OUTINJ - 1 = sequential, 2 = simultaneous" 020020 Units ="n/a" 020100 Address =0x2B0B5 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x78E7 000100 Cat0ID =0x7 020005 Title ="Injector High Slope" 020011 DescSize =0x1CA 020010 Desc ="AHISL - The injector primary fuel slope, used in conjunction with the 'Injector Low Slope' (aka ALOSL) to calculate injection pulsewidths greater than those using the low slope alone. Set to the mass flow rate of an individual fuel injector. When altered, the following parameters will need adjusting too;\r\n\r\n'Injector Low Slope' (aka ALOSL)\r\n'Injector Breakpoint' (aka FN389)\r\n'Injector Offset vs Voltage' (aka FN367)\r\n'Cranking Fuel PW vs ECT' (aka FN348)" 020020 Units ="lb/hr" 020050 SizeInBits =0x10 020100 Address =0x2A512 020150 Flags =0x2 020200 Equation =X/582.535278,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6047 000100 Cat0ID =0x7 020005 Title ="Injector Low Slope" 020011 DescSize =0x338 020010 Desc ="ALOSL - Used to calculate the injection pulsewidth during cranking and short pulsewidths. Set to a value larger than actual injector size to compensate for non linear opening at short durations. Typically 1.33 * 'Injector High Slope' (aka AHISL) for 19 lb/hr injectors reducing to 1.08 * 'Injector High Slope' (aka AHISL) for 83 lb/hr injectors. When altered, the following parameters will need adjusting too;\r\n\r\n'Injector Breakpoint' (aka FN389)\r\n'Injector Offset vs Voltage' (aka FN367)\r\n'Cranking Fuel PW vs ECT' (aka FN3\r\n\r\nAn alternative is to set this parameter to the same value as the 'Injector High Slope' (aka AHISL) in which case the 'Injector Breakpoint' (aka FN389) parameter is not used. The 'Injector Offset vs Voltage' (aka FN367) is critical in getting accurate fuel pulsewidths with this method of tuning." 020020 Units ="lb/hr" 020050 SizeInBits =0x10 020100 Address =0x2A510 020150 Flags =0x2 020200 Equation =X/582.535278,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6E2F 000100 Cat0ID =0x1 020005 Title ="Injector Timing Delay" 020011 DescSize =0xB5 020010 Desc ="IDKADD - Injector timing delay added to the result of the 'Injector Timing' (aka FN1315) lookup following multiplication by the 'Injector Timing Multiplier (aka IDKMUL) parameter. " 020020 Units ="crank deg" 020050 SizeInBits =0x10 020100 Address =0x2A4F2 020150 Flags =0x2 020200 Equation =X/16,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6D7B 000100 Cat0ID =0x1 020005 Title ="Injector Timing Multiplier" 020011 DescSize =0x58 020010 Desc ="IDKMUL - A multiplier of the result of the 'Injector Timing' (aka FN1315) table lookup." 020020 Units ="multiplier" 020050 SizeInBits =0x10 020100 Address =0x2A4F0 020150 Flags =0x2 020200 Equation =X/32768,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x591E 000100 Cat0ID =0x7 020005 Title ="Injector Timing Time Constant" 020011 DescSize =0xE3 020010 Desc ="TCINJD - The time constant for the rolling average calculation of the 'Injector Delay' (aka INJDLY) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x2ADD8 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x29FD 000100 Cat0ID =0x7 020005 Title ="Injector Timing Value at Idle" 020011 DescSize =0x7C 020010 Desc ="MIDTV - Injector timing value used when in drive and the 'Enable Special Injector Timing at Idle' (aka CIDRSW) flag is set." 020020 Units ="crank deg" 020100 Address =0x2B0BF 020200 Equation =X*4,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x389B 000100 Cat0ID =0x7 020005 Title ="Injector Timing Value for MFA" 020011 DescSize =0x105 020010 Desc ="MINTV - The injector timing value used when in fuel economy mode, it overrides all other injector timing parameters. Can indicate the start or end timing point of the injector pulse depending on the setting of the 'Injector Timing Edge' (aka INJREF) parameter." 020020 Units ="crank deg" 020100 Address =0x2B0BE 020200 Equation =X*4,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x25F 000100 Cat0ID =0x7 020005 Title ="Injector Timing Value in Neutral" 020011 DescSize =0xC0 020010 Desc ="CINTV - Injector timing value used when the 'Enable Special Injector Timing in Neutral' (aka CINTSW) flag is set providing the startup delay for fixed injector timing conditions have expired." 020020 Units ="crank deg" 020100 Address =0x2A4D3 020200 Equation =X*4,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x501F 000100 Cat0ID =0x7 020005 Title ="Injectors Per Output Port" 020011 DescSize =0x3C 020010 Desc ="INJOUT - The number of injectors fired by each output port." 020020 Units ="no." 020100 Address =0x2B0B3 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1478 000100 Cat0ID =0x7 020005 Title ="Intake Air Control Valve Open RPM" 020011 DescSize =0x7B 020010 Desc ="NIAC - RPM at which the intake manifold air control valve is opened. Requires 'Auxillary Hardware Present' to be set to 3." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2A314 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2EFD 000100 Cat0ID =0x7 020005 Title ="Intake Air Control Valve Open RPM Hysteresis" 020011 DescSize =0x7D 020010 Desc ="NIACH - Subtracted from 'Intake Air Control Valve Open RPM' to establish rpm at which valve closes. Typically set at 500rpm." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2A316 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5709 000100 Cat0ID =0x6 020005 Title ="ISC Air Drive To Neutral" 020011 DescSize =0x6 020010 Desc ="DNPPM" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2A54E 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x5708 000100 Cat0ID =0x6 020005 Title ="ISC Air Neutral To Drive" 020011 DescSize =0x6 020010 Desc ="NDPPM" 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2A54C 020150 Flags =0x2 020200 Equation =X/2048,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x560B 000100 Cat0ID =0x6 020005 Title ="ISC C/L RPM Correction Airmass Max" 020011 DescSize =0x5B 020010 Desc ="PSIBRM - The maximum value of the 'ISC C/L RPM Correction Airmass' (aka IPSIBR) permitted." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2A51E 020150 Flags =0x2 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x560C 000100 Cat0ID =0x6 020005 Title ="ISC C/L RPM Correction Airmass Min" 020011 DescSize =0x5B 020010 Desc ="PSIBRN - The minimum value of the 'ISC C/L RPM Correction Airmass' (aka IPSIBR) permitted." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2A520 020150 Flags =0x3 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x127 000100 Cat0ID =0x9 020005 Title ="ISC C/L RPM Correction Airmass Test Max" 020011 DescSize =0x6C 020010 Desc ="VSIBRM - The maximum value of the 'ISC C/L RPM Correction Airmass' (aka IPSIBR) permitted during self test." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2B40A 020150 Flags =0x3 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x29E4 000100 Cat0ID =0x9 020005 Title ="ISC C/L RPM Correction Test Rate" 020011 DescSize =0x66 020010 Desc ="V860 - Substitution value used instead of 'ISC C/L RPM Correction Rate' value when in self test mode." 020020 Units ="rate" 020050 SizeInBits =0x10 020100 Address =0x2B4A8 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1BFE 000100 Cat0ID =0x9 020005 Title ="ISC C/L RPM Correction Airmass Test Min" 020011 DescSize =0x6C 020010 Desc ="VSIBRN - The minimum value of the 'ISC C/L RPM Correction Airmass' (aka IPSIBR) permitted during self test." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x2B4A2 020150 Flags =0x3 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x58D8 000100 Cat0ID =0x9 020005 Title ="ISC High RPM Test Delay Time" 020011 DescSize =0x7 020010 Desc ="VISDL1" 020020 Units ="secs" 020100 Address =0x2B494 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x787C 000100 Cat0ID =0x9 020005 Title ="ISC High RPM Test RPM" 020011 DescSize =0x7 020010 Desc ="ISUBND" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x2B498 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x563D 000100 Cat0ID =0x6 020005 Title ="ISC Gain Associated With The Desired DASPOT Airflow" 020011 DescSize =0x7 020010 Desc ="DASPTK" 020020 Units ="lb/min per TP count" 020050 SizeInBits =0x10 020100 Address =0x2A526 020150 Flags =0x2 020200 Equation =X/1048576,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x62AD 000100 Cat0ID =0x6 020005 Title ="ISC Gain For Overspeed in Drive" 020011 DescSize =0x7E 020010 Desc ="KPSIDD - Multiplied by engine speed error and the 'ISC Gain vs RPM Error' lookup result, used as input in IPSIBR calculation." 020020 Units ="lb/min per rpm" 020050 SizeInBits =0x10 020100 Address =0x2A51C 020150 Flags =0x2 020200 Equation =X/4194304,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x69C2 000100 Cat0ID =0x6 020005 Title ="ISC Gain For Overspeed in Neutral" 020011 DescSize =0x7E 020010 Desc ="KPSIND - Multiplied by engine speed error and the 'ISC Gain vs RPM Error' lookup result, used as input in IPSIBR calculation." 020020 Units ="lb/min per rpm" 020050 SizeInBits =0x10 020100 Address =0x2A518 020150 Flags =0x2 020200 Equation =X/4194304,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x551B 000100 Cat0ID =0x9 020005 Title ="ISC Gain For Overspeed in Self Test" 020011 DescSize =0x51 020010 Desc ="VPSIND - Multiplied by engine speed error, used as input in IPSIBR calculation. " 020020 Units ="lb/min per rpm" 020050 SizeInBits =0x10 020100 Address =0x2B4A4 020150 Flags =0x2 020200 Equation =X/4194304,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x7619 000100 Cat0ID =0x6 020005 Title ="ISC Gain For Underspeed in Drive" 020011 DescSize =0x7E 020010 Desc ="KPSIDU - Mu