XDF 1.110000 DO NOT HAND EDIT!!!! (Trust me) %%HEADER%% 001000 FileVers ="110408" 001005 DefTitle ="GUFB" 001007 DescSize =0x10B 001006 Desc ="Covers A9L, A9M, A3M, A3M1, A3M2, D3D1, S0Z and X3Z ecu's. Requires 64k bin file, first 8k to be 'padded' with null data .If you find any errors, or can add anything new, please post a topic on the Ford definition forum at http://forum.tunerpro.net/viewforum.php?f=8" 001010 Author ="" 001030 BinSize =0x10000 001035 BaseOffset =0 001200 ADSAssoc ="" 001225 ADSCheck =0x0 001300 GenFlags =0x0 001325 ModeFlags =0x0 002000 Category0 ="Fuel" 002001 Category1 ="Spark" 002002 Category2 ="Sensors" 002003 Category3 ="Limits" 002004 Category4 ="Miscellaneous" 002005 Category5 ="Idle" 002006 Category6 ="Hardware" 002007 Category7 ="Scalers" 002008 Category8 ="Tests" 002009 Category9 ="Adaptive Learning" 002010 Category10 ="Failure Management" 002011 Category11 ="EGR" 002012 Category12 ="Purge" 002013 Category13 ="Accessories" 002014 Category14 ="Economy Mode" 002015 Category15 ="Transmission" 002016 Category16 ="Cruise Control" 002017 Category17 ="Transient Fuel" 002019 Category19 ="Unknown" %%END%% %%CONSTANT%% 000002 UniqueID =0x6182 000100 Cat0ID =0xE 020005 Title ="A/C Clutch Engage Max Temp" 020011 DescSize =0x5 020010 Desc ="CTAC" 020020 Units ="deg F" 020100 Address =0x9402 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4653 000100 Cat0ID =0xE 020005 Title ="A/C Clutch Engage Max Temp Hysteresis" 020011 DescSize =0x6 020010 Desc ="CTACH" 020020 Units ="deg F" 020100 Address =0x9403 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xEDA 000100 Cat0ID =0xE 020005 Title ="A/C Clutch Engage Min RPM" 020011 DescSize =0x7 020010 Desc ="ACOFFN" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9404 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2B7B 000100 Cat0ID =0xE 020005 Title ="A/C Clutch Engage Min RPM Hysteresis" 020011 DescSize =0x7 020010 Desc ="ACOFFH" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9406 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5960 000100 Cat0ID =0xE 020005 Title ="A/C Clutch Idle Engage Delay Time" 020011 DescSize =0x7 020010 Desc ="IDLCOT" 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x9400 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7FD3 000100 Cat0ID =0xE 020005 Title ="A/C Clutch Min Disable Time" 020011 DescSize =0x7 020010 Desc ="ACMNDT" 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x93FE 020150 Flags =0x2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x508A 000100 Cat0ID =0xE 020005 Title ="A/C Clutch Min Enable Time" 020011 DescSize =0x7 020010 Desc ="ACMNET" 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x940C 020150 Flags =0x2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x29D6 000100 Cat0ID =0xE 020005 Title ="A/C Disable Time After Start" 020011 DescSize =0x51 020010 Desc ="ACSTRD - The maximum time that the aircon clutch is disabled for after start up." 020020 Units ="secs" 020100 Address =0x93FB 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5908 000100 Cat0ID =0xE 020005 Title ="A/C Disable Time Due to Brake" 020011 DescSize =0xA4 020010 Desc ="BRKCOT - The maximum time that the aircon clutch is disabled for when the brake is applied. Set to zero to eliminate the brake having any effect on aircon control." 020020 Units ="secs" 020100 Address =0x93FC 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x24CA 000100 Cat0ID =0x7 020005 Title ="A/C Low Speed Fan MPH" 020011 DescSize =0x5F 020010 Desc ="LSFVS - The minimum mph to turn off the low speed fan when it is being used for the a/c alone." 020020 Units ="mph" 020100 Address =0x9417 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1BB0 000100 Cat0ID =0x7 020005 Title ="A/C Low Speed Fan MPH Hysteresis" 020011 DescSize =0x21 020010 Desc ="LSFVSH - Typically set to 5 mph." 020020 Units ="mph" 020100 Address =0x9418 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x131B 000100 Cat0ID =0xE 020005 Title ="A/C Min Time Off Before Turning Fan Off" 020011 DescSize =0xCF 020010 Desc ="ACMNFT - The minimum time that the A/C clutch must be disengaged for before the low speed fan is turned off. Used to avoid excessive on/off fan cycling.\r\n\r\nConversion to be determined, value looks too high." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x941A 020150 Flags =0x2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4BB7 000100 Cat0ID =0xE 020005 Title ="A/C Recognition Time Threshold" 020011 DescSize =0x5 020010 Desc ="ACRT" 020020 Units ="mSecs" 020050 SizeInBits =0x10 020100 Address =0x93B2 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2FF6 000100 Cat0ID =0xE 020005 Title ="A/C WOT Cutout Threshold" 020011 DescSize =0x28 020010 Desc ="THBP4 - Added to closed throttle value." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x9408 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x11D4 000100 Cat0ID =0xE 020005 Title ="A/C WOT Cutout Threshold Hysteresis" 020011 DescSize =0x7 020010 Desc ="THBP4H" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x940A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3EB0 000100 Cat0ID =0xE 020005 Title ="A/C WOT Cutout Time" 020011 DescSize =0x40 020010 Desc ="ACWDLY - Duration the A/C clutch is disengaged for when at WOT." 020020 Units ="secs" 020100 Address =0x93FD 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5938 000100 Cat0ID =0x9 020005 Title ="A/F Ratio for Goose Test" 020011 DescSize =0xB 020010 Desc ="V_KNK_FUEL" 020020 Units ="A/F Ratio" 020050 SizeInBits =0x10 020100 Address =0x8F5A 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4B2D 000100 Cat0ID =0x9 020005 Title ="A/F Ratio for Self Test" 020011 DescSize =0x6 020010 Desc ="VRLAM" 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x9E86 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x38A7 000100 Cat0ID =0x9 020005 Title ="A/F Ratio Rich Limit" 020011 DescSize =0x44 020010 Desc ="REQV - Desired A/F ratio is clipped to this limit during self test." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x9E82 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4D1 000100 Cat0ID =0x9 020005 Title ="A/F Ratio Lean Limit" 020011 DescSize =0x44 020010 Desc ="LEQV - Desired A/F ratio is clipped to this limit during self test." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x9E84 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x114E 000100 Cat0ID =0x1 020005 Title ="Accel Enrichment Global Multiplier" 020011 DescSize =0xAD 020010 Desc ="AEM - A multiplier of the result of the 'Accel Enrichment Fuel' (aka FN1303) table lookup.\r\nMultiplier values less than 1 reduce fuel, values greater than 1 increase fuel." 020020 Units ="multiplier" 020100 Address =0x9002 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1EA2 000100 Cat0ID =0x5 020005 Title ="Accel Enrichment Load Time Constant" 020011 DescSize =0xEA 020010 Desc ="TCAELD - The time constant for the rolling average calculation of the 'Accel Enrichment Load' (aka AELOAD) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97FC 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x96E 000100 Cat0ID =0x1 020005 Title ="Accel Enrichment Minimum" 020011 DescSize =0x31 020010 Desc ="MINAE\r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x9AA6 020150 Flags =0x2 020200 Equation =X/262144,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x527F 000100 Cat0ID =0x1 020005 Title ="Accel Enrichment Min Delta Load" 020011 DescSize =0x51 020010 Desc ="AEACLD - The change in load required to indicate the intake manifold is filling." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x9008 020150 Flags =0x3 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5544 000100 Cat0ID =0x1 020005 Title ="Accel Enrichment Min Throttle Rate" 020011 DescSize =0x67 020010 Desc ="AETAR - The rate of throttle change must be greater than this value to enable acceleration enrichment." 020020 Units ="deg/sec" 020100 Address =0x900A 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x52DD 000100 Cat0ID =0x11 020005 Title ="Acceleration Button Maximum" 020011 DescSize =0x5D 020010 Desc ="HACCEL - Highest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E78 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7759 000100 Cat0ID =0x11 020005 Title ="Acceleration Button Minimum" 020011 DescSize =0x5C 020010 Desc ="LACCEL - Lowest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E76 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2C34 000100 Cat0ID =0x11 020005 Title ="Acceleration Ramp Rate" 020011 DescSize =0x4F 020010 Desc ="ACLINC - The rate of acceleration from the current speed to the desired speed." 020020 Units ="mph/sec" 020050 SizeInBits =0x10 020100 Address =0x8E98 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x556F 000100 Cat0ID =0x1 020005 Title ="ACT Fraction for Accel Enrichment" 020011 DescSize =0x187 020010 Desc ="FRCTAE - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the input value to the 'Accel Enrichment Fuel Scaler for ACT to ECT' (aka FN020B) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0x900B 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5BA0 000100 Cat0ID =0x2 020005 Title ="ACT Fraction for Base Dwell" 020011 DescSize =0x1CC 020010 Desc ="DWLWF - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the calculation of the estimated coil temperature value. This estimated value is checked against the 'Dwell Time Table Select Temperature' (aka DWLTMP) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0x945A 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5540 000100 Cat0ID =0x12 020005 Title ="ACT Fraction for Transient Fuel" 020011 DescSize =0x174 020010 Desc ="ALPHA - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the input value to the 'Fuel Scaler for ACT to ECT' (aka FN022) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0x9000 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x35AA 000100 Cat0ID =0x1 020005 Title ="ACT Fraction for Fuel Base Table" 020011 DescSize =0x175 020010 Desc ="FRCBFT - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the input value to the 'Fuel Scaler for ACT to ECT' (aka FN022) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0x9AB3 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5296 000100 Cat0ID =0x1 020005 Title ="ACT Fraction for Fuel Startup Table" 020011 DescSize =0x175 020010 Desc ="FRCSFT - The ACT to ECT proportioning factor used to determine the fraction of ACT to ECT for the input value to the 'Fuel Scaler for ACT to ECT' (aka FN022) parameter. Higher values increase the contribution from ACT. Set to zero to run the tables associated with this parameter off ECT alone. Set to 1.000 to run the tables associated with this parameter off ACT alone. " 020020 Units ="multiplier" 020100 Address =0x9AB4 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7A52 000100 Cat0ID =0x1 020005 Title ="ACT Fraction for Spark" 020011 DescSize =0x35 020010 Desc ="FRCSPK - \r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="multiplier" 020100 Address =0x9441 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%TABLE%% 000002 UniqueID =0x445B 000100 Cat0ID =0xE 000101 Cat1ID =0xFF 040005 Title ="A/C WOT Cutout Time vs TP" 040011 DescSize =0x6D 040010 Desc ="FN087 - The maximum time the A/C clutch is disengaged at WOT. The input value is relative throttle position." 040020 SubType =0x7 040100 Address =0x0 040150 Flags =0x300 040200 ZEq =X,TH|0|0|0|0| 040304 YOutType =0x2 040230 RangeLow =0.0000 040240 RangeHigh =255.0000 040300 Rows =0x6 040305 Cols =0x1 040320 XUnits ="volts" 040325 YUnits ="secs" 040330 ZUnits ="" 040350 XLabels =X,Y 040352 XLabelType =0x4 040354 XEq =X/12800,TH|0|0|0|0| 040360 YLabels = 040362 YLabelType =0x4 040364 YEq =X,TH|0|0|0|0| 040600 XAddress =0x8D56 040650 XOutputDig =0x3 040660 XAxisMin =1000.000000 040670 XAxisMax =1000.000000 040700 YAddress =0x8D58 040750 YOutputDig =0x1 040760 YAxisMin =1000.000000 040770 YAxisMax =1000.000000 %%END%% %%CONSTANT%% 000002 UniqueID =0x6D2D 000100 Cat0ID =0x9 020005 Title ="ACT KOEO Max" 020011 DescSize =0x7 020010 Desc ="VIACT2" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F4A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3442 000100 Cat0ID =0x9 020005 Title ="ACT KOEO Min" 020011 DescSize =0x7 020010 Desc ="VIACT1" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F48 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x29F0 000100 Cat0ID =0x9 020005 Title ="ACT KOER Max" 020011 DescSize =0x7 020010 Desc ="VIACT4" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F4E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2C28 000100 Cat0ID =0x9 020005 Title ="ACT KOER Min" 020011 DescSize =0x7 020010 Desc ="VIACT3" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F4C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7563 000100 Cat0ID =0x4 020005 Title ="ACT Max" 020011 DescSize =0x53 020010 Desc ="ACTMAX - Value at which the eec considers that the sensor has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8EC4 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5153 000100 Cat0ID =0x4 020005 Title ="ACT Min" 020011 DescSize =0x54 020010 Desc ="ACTMIN - Value at which the eec considers that the sensor has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8EC2 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x362D 000100 Cat0ID =0x12 020005 Title ="Actual Intake Surface Fuel Multiplier" 020011 DescSize =0x61 020010 Desc ="AISFM - Multiplier of 'Actual_Intake_Surface_Fuel' (aka AISF) during deceleration fuel shut off." 020020 Units ="multiplier" 020100 Address =0x9AC2 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4F4D 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Accel Enrichment Max" 020011 DescSize =0x69 020010 Desc ="AELIM - The maximum acceleration enrichment fuel flow permitted in order for adaptive learning to occur." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x9AF0 020150 Flags =0x2 020200 Equation =X/512,TH|0|0|0|0| 020210 DecimalPl =0x5 %%END%% %%CONSTANT%% 000002 UniqueID =0x61CC 000100 Cat0ID =0xA 020005 Title ="Adaptive Control ACT Max" 020011 DescSize =0x7 020010 Desc ="AFACT2" 020020 Units ="deg F" 020100 Address =0x9AE5 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x619D 000100 Cat0ID =0xA 020005 Title ="Adaptive Control ACT Min" 020011 DescSize =0x7 020010 Desc ="AFACT1" 020020 Units ="deg F" 020100 Address =0x9AE4 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4DA7 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Deadband" 020011 DescSize =0x335 020010 Desc ="DELAMB - This value is used to form the deadband around stoichiometric within which the adaptive learning loop counter values are not altered.\r\n\r\nWhen the HEGO is reporting a rich condition this parameter's value is added to the resultant value created by adding the HEGO Bias value to the stoichiometric A/F ratio to establish a lean A/F ratio which if greater than the lean 'Desired A/F Ratio' (aka LAMBSE) value being commanded then the loop counter incrementing does not occur.\r\n\r\nWhen the HEGO is reporting a lean condition this parameter's value is subtracted from the resultant value created by adding the HEGO Bias value to the stoichiometric A/F ratio to establish a rich A/F ratio which if less than the rich 'Desired A/F Ratio' (aka LAMBSE) value being commanded then loop counter incrementing does not occur." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x9AE8 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2274 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Delay Time" 020011 DescSize =0xCD 020010 Desc ="ADAPTM - The time delay before adaptive learning is permitted once the ECT is between the values set by the 'Adaptive Control ECT Min' (aka AFECT1) and 'Adaptive Control ECT Max' (aka AFECT2) parameters." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x9AE6 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2AF1 000100 Cat0ID =0xA 020005 Title ="Adaptive Control ECT Max" 020011 DescSize =0xBD 020010 Desc ="AFECT2 - Temperature at which the 'Adaptive Fuel Timer' (aka ADPTMR) is reset to zero.\r\n\r\nSee 'Adaptive Control Delay Time' (aka ADAPTM) for more information on how this parameter is used." 020020 Units ="deg F" 020100 Address =0x9AE3 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3DA 000100 Cat0ID =0xA 020005 Title ="Adaptive Control ECT Min" 020011 DescSize =0xB8 020010 Desc ="AFECT1 - Temperature at which the 'Adaptive Fuel Timer' (aka ADPTMR) is started.\r\n\r\nSee 'Adaptive Control Delay Time' (aka ADAPTM) for more information on how this parameter is used." 020020 Units ="deg F" 020100 Address =0x9AE2 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6265 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Fast HEGO Count" 020011 DescSize =0xE8 020010 Desc ="FAEGCT - The minimum number of HEGO counts required for adaptive learning to take place when the number of KAM warm ups is less than the 'Adaptive Control Max Warm Up Cycles' value. Lower values increase the adaptive learning rate." 020020 Units ="counts" 020100 Address =0x9AF7 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x68D7 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Max" 020011 DescSize =0x39 020010 Desc ="MAXADP - The maximum value that KAMREF is allowed to be." 020020 Units ="multiplier" 020100 Address =0x9AEF 020150 Flags =0x8 020200 Equation =(X/256)+0.5,TH|0|0|0|0| 020210 DecimalPl =0x3 020240 RangeHigh =128.0000 %%END%% %%CONSTANT%% 000002 UniqueID =0x6266 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Max Warm Up Cycles" 020011 DescSize =0x91 020010 Desc ="KWUCNT - The maximum number of warm up cycles to use the faster adaptive learning update rate. Beyond this value the normal update rate is used." 020020 Units ="no." 020100 Address =0x9AF8 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4904 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Min" 020011 DescSize =0x39 020010 Desc ="MINADP - The minimum value that KAMREF is allowed to be." 020020 Units ="multiplier" 020100 Address =0x9AEE 020150 Flags =0x8 020200 Equation =(X/256)+0.5,TH|0|0|0|0| 020210 DecimalPl =0x3 020240 RangeHigh =128.0000 %%END%% %%CONSTANT%% 000002 UniqueID =0x44DB 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Table Column Lockout" 020011 DescSize =0x124 020010 Desc ="DELCOL - If the difference between the current adaptive control learning table column (aka NRMCES) and the last adaptive control learning table column (aka LSTCOL) is greater than this value then adaptive learning is disabled. Used to reduce the effect of excessive transient changes in rpm." 020020 Units ="column" 020050 SizeInBits =0x10 020100 Address =0x9AEC 020150 Flags =0x2 020200 Equation =X/256,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x40E3 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Table Row Lockout" 020011 DescSize =0x11F 020010 Desc ="DELROW - If the difference between the current adaptive control learning table row (aka NRMRLD) and the last adaptive control learning table row (aka LSTROW) is greater than this value then adaptive learning is disabled. Used to reduce the effect of excessive transient changes in load." 020020 Units ="row" 020050 SizeInBits =0x10 020100 Address =0x9AEA 020150 Flags =0x2 020200 Equation =X/256,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x46B4 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Normal HEGO Count" 020011 DescSize =0xB9 020010 Desc ="ADEGCT - The minimum number of HEGO counts required for adaptive learning to take place when the number of KAM warm ups is greater than the 'Adaptive Control Max Warm Up Cycles' value." 020020 Units ="counts" 020100 Address =0x9AF6 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x285A 000100 Cat0ID =0xA 020005 Title ="Adaptive Control Transient Fuel Max" 020011 DescSize =0x6E 020010 Desc ="ADEFTR - The maximum transient fuel compensation fuel flow permitted in order for adaptive learning to occur." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x9AF4 020150 Flags =0x3 020200 Equation =X/65536,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x596F 000100 Cat0ID =0xE 020005 Title ="Adjustable Damper Min Air Charge" 020011 DescSize =0x3F 020010 Desc ="SHKCHG - The minimum air charge to indicate hard acceleration." 020020 Units ="lb/intake" 020050 SizeInBits =0x10 020100 Address =0x9410 020150 Flags =0x2 020200 Equation =X/16777216,TH|0|0|0|0| 020210 DecimalPl =0x7 %%END%% %%CONSTANT%% 000002 UniqueID =0x7EE9 000100 Cat0ID =0xE 020005 Title ="Adjustable Damper Min TP" 020011 DescSize =0x51 020010 Desc ="SHKTP - The minimum voltage above closed throttle to indicate hard acceleration." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x9412 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5599 000100 Cat0ID =0xB 020005 Title ="Airmass Flow Min For TP Calculation" 020011 DescSize =0xCE 020010 Desc ="IDLMAF - If the airmass is less than this then the eec sets the throttle value equal to the closed throttle value if either the TPS has failed, is less than 'TPS Max' value or greater than 'TPS Max' value." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x942C 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x45FE 000100 Cat0ID =0xA 020005 Title ="Allow Adaptive Learning" 020011 DescSize =0xA8 020010 Desc ="Z_ADPSW - Set to \"4700\" to permit adaptive learning to occur, change to \"480F\" to disable adaptive learning.\r\n\r\nWARNING: Do not use any values other than one of these." 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x21B4 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4D2A 000100 Cat0ID =0x9 020005 Title ="Allow MIL Bulb Check" 020011 DescSize =0x6E 020010 Desc ="MILLIM - Setting to any value other than zero will permit the MIL bulb check to be performed during cranking." 020020 Units ="n/a" 020050 SizeInBits =0x10 020100 Address =0x8F74 020150 Flags =0x2 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5186 000100 Cat0ID =0xE 020005 Title ="Alternator Control Cold Start Delay #1" 020011 DescSize =0x6 020010 Desc ="EDTM1" 020020 Units ="secs" 020100 Address =0x93EB 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x387B 000100 Cat0ID =0xE 020005 Title ="Alternator Control Cold Start Delay #2" 020011 DescSize =0x6 020010 Desc ="EDTM4" 020020 Units ="secs" 020100 Address =0x93EC 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7A57 000100 Cat0ID =0xE 020005 Title ="Alternator Control Hot Start Delay" 020011 DescSize =0x6 020010 Desc ="EDTM3" 020020 Units ="secs" 020100 Address =0x93E8 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x57C5 000100 Cat0ID =0xE 020005 Title ="Alternator Control Max Temp" 020011 DescSize =0x57 020010 Desc ="ECADECT - Below this temperature the alternator may be permitted to run at half speed." 020020 Units ="deg F" 020100 Address =0x93E2 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x55B0 000100 Cat0ID =0xE 020005 Title ="Alternator Control Max Temp Hysteresis" 020011 DescSize =0x4A 020010 Desc ="EDETHYS - Hysteresis value subtracted from 'Alternator Control Max Temp'." 020020 Units ="deg F" 020100 Address =0x93E5 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x858 000100 Cat0ID =0xE 020005 Title ="Alternator Control Min MPH" 020011 DescSize =0x5B 020010 Desc ="ECADVS - The minimum mph required for the alternator to be permitted to run at half speed." 020020 Units ="mph" 020100 Address =0x93E4 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x42E5 000100 Cat0ID =0xE 020005 Title ="Alternator Control Min MPH Hysteresis" 020011 DescSize =0x60 020010 Desc ="EDVSHYS - Hysteresis value subtracted from 'Alternator Control Min MPH' (aka ECADVS) parameter." 020020 Units ="mph" 020100 Address =0x93E7 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6CD1 000100 Cat0ID =0xE 020005 Title ="Alternator Control Min RPM" 020011 DescSize =0x5A 020010 Desc ="ECADN - The minimum rpm required for the alternator to be permitted to run at half speed." 020020 Units ="rpm" 020100 Address =0x93E3 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7C01 000100 Cat0ID =0xE 020005 Title ="Alternator Control Min RPM Hysteresis" 020011 DescSize =0x5E 020010 Desc ="EDNHYS - Hysteresis value subtracted from 'Alternator Control Min RPM' (aka ECADN) parameter." 020020 Units ="rpm" 020100 Address =0x93E6 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6B94 000100 Cat0ID =0xE 020005 Title ="Alternator Control Warm Start Delay #1" 020011 DescSize =0x6 020010 Desc ="EDTM2" 020020 Units ="secs" 020100 Address =0x93E9 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2369 000100 Cat0ID =0xE 020005 Title ="Alternator Control Warm Start Delay #2" 020011 DescSize =0x6 020010 Desc ="EDTM5" 020020 Units ="secs" 020100 Address =0x93EA 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x24BA 000100 Cat0ID =0x9 020005 Title ="AM2 Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT1 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F7C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5C4 000100 Cat0ID =0x9 020005 Title ="AM1 Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT2 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F7E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E0B 000100 Cat0ID =0x7 020005 Title ="Auxiliary Hardware Present" 020011 DescSize =0xD0 020010 Desc ="THRMHP - The four possible settings are;\r\n\r\n0 = None of the following hardware is present\r\n1 = Thermactor hardware present\r\n2 = Supercharger bypass valve present\r\n3 = Inlet manifold air control valve present" 020020 Units ="" 020100 Address =0x9E65 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3492 000100 Cat0ID =0x9 020005 Title ="Battery Voltage Lower Limit" 020011 DescSize =0xA 020010 Desc ="VKYPWR - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8EAC 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6130 000100 Cat0ID =0x5 020005 Title ="Battery Voltage Time Constant" 020011 DescSize =0xE2 020010 Desc ="TCVBAT - The time constant for the rolling average calculation of the 'Battery Voltage' (aka VBAT) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97F8 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6B6E 000100 Cat0ID =0x9 020005 Title ="BP Max During Test" 020011 DescSize =0x7 020010 Desc ="VBPDL2" 020020 Units ="clock ticks" 020050 SizeInBits =0x10 020100 Address =0x8F5E 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xC47 000100 Cat0ID =0x9 020005 Title ="BP Max Time Between Update" 020011 DescSize =0x7 020010 Desc ="VBPMAX" 020020 Units ="secs" 020100 Address =0x8F70 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3AF5 000100 Cat0ID =0x9 020005 Title ="BP Min During Test" 020011 DescSize =0x7 020010 Desc ="VBPDL1" 020020 Units ="clock ticks" 020050 SizeInBits =0x10 020100 Address =0x8F5C 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x60A6 000100 Cat0ID =0x3 020005 Title ="BP Time Constant" 020011 DescSize =0xF2 020010 Desc ="TCBBAR - The time constant for the rolling average calculation of the 'BP' (aka BP) and 'BP Average' (aka BAPBAR) values.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97FE 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x530D 000100 Cat0ID =0x11 020005 Title ="Buttons Not Pressed Maximum" 020011 DescSize =0x60 020010 Desc ="HIHOLD - Highest value of Vehicle Speed Control Command Switch to indicate no button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E80 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x52E0 000100 Cat0ID =0x11 020005 Title ="Buttons Not Pressed Minimum" 020011 DescSize =0x5F 020010 Desc ="LOHOLD - Lowest value of Vehicle Speed Control Command Switch to indicate no button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E7E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xF37 000100 Cat0ID =0x6 020005 Title ="Buzz RPM" 020011 DescSize =0x53 020010 Desc ="BZZRPM - Additional rpm added to base target idle rpm at start up to clear engine." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x904E 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6BCB 000100 Cat0ID =0x6 020005 Title ="Buzz RPM Time" 020011 DescSize =0x7C 020010 Desc ="BZZTM - Duration that 'Buzz RPM' (aka BZZRPM) is added to base target idle rpm at startup. \r\n\r\nConversion to be determined." 020020 Units ="secs" 020100 Address =0x9067 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x56A5 000100 Cat0ID =0x1 020005 Title ="C/L Neutral Idle Fuel Max Time" 020011 DescSize =0xE9 020010 Desc ="NIOLD - If the 'Close Throttle Neutral Timer' (aka CTNTMR) exceeds this value then open loop mode is used when in neutral at idle. This value is only checked by the eec when at closed throttle. Set to '255' to disable this function." 020020 Units ="secs" 020100 Address =0x9048 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3E9E 000100 Cat0ID =0x9 020005 Title ="Canister Purge Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT5 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F84 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x13DF 000100 Cat0ID =0xD 020005 Title ="Canister Purge Min RPM" 020011 DescSize =0x44 020010 Desc ="EVRPM - \r\n\r\nDoes not appear to be used by the eec in this strategy." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x93F2 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6A19 000100 Cat0ID =0xD 020005 Title ="Canister Purge Min RPM Hysteresis" 020011 DescSize =0x45 020010 Desc ="EVRPMH - \r\n\r\nDoes not appear to be used by the eec in this strategy." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x93F4 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x131E 000100 Cat0ID =0x5 020005 Title ="Checksum" 020011 DescSize =0x9F 020010 Desc ="CHKSUM - Do not edit. This is recalculated automatically when the bin is saved. When emulating, upload this new checksum to the emulator after saving the bin." 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x200A 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7F06 000100 Cat0ID =0xA 020005 Title ="Clear KAM" 020011 DescSize =0x1C6 020010 Desc ="Z_KAMCLR - Forces the re-initialisation of the Keep Alive Memory so that all adaptive learning information is cleared.\r\n\r\nNormally set to \"235D\", change this to \"2382\" to clear the KAM (either during running if your emulator permits 'on the fly' changes or by cycling the key to 'run' and then off) and then restore back to the original value. Does not affect the KAM during KOEO or KEOR tests.\r\n\r\nWARNING: Do not use any values other than one of these." 020020 Units ="" 020050 SizeInBits =0x10 020100 Address =0x218C 020150 Flags =0x2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x52DB 000100 Cat0ID =0x11 020005 Title ="Coast Button Maximum" 020011 DescSize =0x5D 020010 Desc ="HCOAST - Highest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E74 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x52DA 000100 Cat0ID =0x11 020005 Title ="Coast Button Minimum" 020011 DescSize =0x5C 020010 Desc ="LCOAST - Lowest value of Vehicle Speed Control Command Switch to indicate button depressed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8E72 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x32B1 000100 Cat0ID =0x1 020005 Title ="Cold Engine Fuel Multiplier Update Time Limit" 020011 DescSize =0xEC 020010 Desc ="MULTM - When the 'Cold Engine Fuel Multiplier Update Timer' (aka MULTMR) exceeds this value then the 'Cold Engine Fuel Multiplier' (aka LAMMUL) value is updated.\r\n\r\nDoes not appear to be used in this ecu, possibly superseded by FN393F." 020020 Units ="secs" 020100 Address =0x9AF9 020150 Flags =0x8 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 020240 RangeHigh =128.0000 %%END%% %%CONSTANT%% 000002 UniqueID =0x3367 000100 Cat0ID =0x5 020005 Title ="Cold Start Max ECT" 020011 DescSize =0x45 020010 Desc ="CTLOW - The maximum ECT for a cold start condition to be recognised." 020020 Units ="deg F" 020100 Address =0x9E5F 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6082 000100 Cat0ID =0x5 020005 Title ="Cranking Mode Exit Min PIPs" 020011 DescSize =0xD7 020010 Desc ="NCNT - Once the ECT sensor has been read 8 times this is the minimum number of PIPs that must occur once the rpm is greater than the 'Cranking Mode Exit Min RPM' (aka NRUN) parameter in order to exit cranking mode." 020020 Units ="no." 020100 Address =0x97BC 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5D9D 000100 Cat0ID =0x5 020005 Title ="Cranking Mode Exit RPM" 020011 DescSize =0xC2 020010 Desc ="NRUN - Once the ECT sensor has been read 8 times this is the minimum rpm required for the 'Cranking Mode Exit Min PIPs' (aka NCNT) parameter to be checked to see if cranking mode can be exited." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x97C2 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x128C 000100 Cat0ID =0x5 020005 Title ="Cranking Mode Re-enter RPM" 020011 DescSize =0x4E 020010 Desc ="NSTALL - If the rpm is less than this value then cranking mode is re-entered." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x97C4 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x34AF 000100 Cat0ID =0x2 020005 Title ="Cranking Mode Spark" 020011 DescSize =0x137 020010 Desc ="Z_CRKSPK - The spark advance used during cranking. Adjust for highly modified engines that will not start with the stock advance value of 10 degrees.\r\n\r\nRequires the use of a \"black\" Computer Controlled Dwell (CCD) TFI module and the 'Computer Controlled Dwell Present' (aka CCDSW) parameter needs to be set.\r\n" 020020 Units ="deg adv" 020100 Address =0x55CA 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x56A6 000100 Cat0ID =0x1 020005 Title ="CT Neutral Timer Hysteresis" 020011 DescSize =0x84 020010 Desc ="NIHYS - Added to 'C/L Neutral Idle Fuel Max Time' to make the upper clip limit of the 'Closed Throttle Neutral Timer' (aka CTNTMR)." 020020 Units ="secs" 020100 Address =0x9049 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x583C 000100 Cat0ID =0x5 020005 Title ="CT Neutral Timer Max RPM" 020011 DescSize =0xF3 020010 Desc ="INLRPM - The base rpm added to the result of the 'CT Neutral Timer RPM Adder' (aka FN880) lookup. This resultant value is the maximum rpm allowed in order for the 'CT Neutral Timer' to count up and the 'CT Neutral Flag (aka CTNFLG) to be set." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x93DA 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7C1 000100 Cat0ID =0x5 020005 Title ="CT Neutral Timer Max RPM Hysteresis" 020011 DescSize =0x4B 020010 Desc ="INLRPH - Hysteresis for the 'CT Neutral Timer Max RPM' (aka INLRPM) value." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x93DC 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5C04 000100 Cat0ID =0x2 020005 Title ="CT Tip In Flag Min Load" 020011 DescSize =0x56 020010 Desc ="TIPLOD - The minimum load in order for the closed throttle tip in flag to be cleared." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x9464 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x257B 000100 Cat0ID =0x2 020005 Title ="CT Tip In Flag Min Load Hysteresis" 020011 DescSize =0x3D 020010 Desc ="TIPHYS - Hysteresis for the 'CT Tip In Flag Min Load' value." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x9466 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2B9F 000100 Cat0ID =0x9 020005 Title ="CT to PT Transitions to Enable HEGO Switch Test" 020011 DescSize =0x7 020010 Desc ="VPTCNT" 020020 Units ="no." 020100 Address =0x8F01 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5A6E 000100 Cat0ID =0x2 020005 Title ="CT Spark Adder" 020011 DescSize =0x30 020010 Desc ="KCS1 - Added to 'CT Spark vs RPM' lookup value." 020020 Units ="deg adv" 020050 SizeInBits =0x10 020100 Address =0x9432 020150 Flags =0x3 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x35EF 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Desired AF Ratio" 020011 DescSize =0x7 020010 Desc ="VLAMCB" 020020 Units ="AF ratio" 020050 SizeInBits =0x10 020100 Address =0x8EF4 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7D76 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Desired RPM" 020011 DescSize =0xA 020010 Desc ="VISCN1 - " 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8EF6 020150 Flags =0x2 020200 Equation =X*8,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1CA8 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Injector Off Time" 020011 DescSize =0x7 020010 Desc ="VCBTM2" 020020 Units ="secs" 020100 Address =0x8EFD 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3D8A 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Injector On Time" 020011 DescSize =0x7 020010 Desc ="VCBTM1" 020020 Units ="secs" 020100 Address =0x8EFC 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4A03 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test RPM Drop" 020011 DescSize =0x7 020010 Desc ="VCBPCT" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x8EF2 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7730 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test RPM Drop Clip" 020011 DescSize =0x7 020010 Desc ="VCBCLP" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x8EEE 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1BC6 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test RPM Drop Increment" 020011 DescSize =0x7 020010 Desc ="VCBPAD" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x8EF0 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1B08 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test RPM Drop Time" 020011 DescSize =0x7 020010 Desc ="VISDL5" 020020 Units ="secs" 020100 Address =0x8EFB 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x540 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Start Delay" 020011 DescSize =0x7 020010 Desc ="VCBDLY" 020020 Units ="secs" 020100 Address =0x8EF8 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x377C 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Time Wait" 020011 DescSize =0x7 020010 Desc ="VISDL4" 020020 Units ="secs" 020100 Address =0x8EFA 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x41FF 000100 Cat0ID =0x9 020005 Title ="Cylinder Balance Test Type" 020011 DescSize =0x54 020010 Desc ="VCBFLG -\r\n\r\n-1 = allow test\r\n 0 = inhibit test\r\n 1 = allow multiple entries to test" 020020 Units ="state" 020100 Address =0x8EF9 020150 Flags =0x1 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5377 000100 Cat0ID =0x6 020005 Title ="Dashpot Min for Declutch" 020011 DescSize =0x12B 020010 Desc ="DASMIN - When at closed throttle this is the minimum dashpot (pre position airflow) allowed when the vehicle speed is greater than the resultant value created by adding the 'Dashpot Min MPH for Declutch' (aka DASMPH) and 'Dashpot Min MPH for Declutch Hysteresis' (aka DASMHYST) parameters together." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x8EA4 020150 Flags =0x2 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x5375 000100 Cat0ID =0x6 020005 Title ="Dashpot Min MPH for Declutch" 020011 DescSize =0xD6 020010 Desc ="DASMPH - When the 'Dashpot Min for Declutch' (aka DASMIN) parameter is being used by the eec this is the minimum vehicle speed required for this minimum dashpot (pre position airflow) to be continue to be applied." 020020 Units ="mph" 020100 Address =0x8EA2 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5376 000100 Cat0ID =0x6 020005 Title ="Dashpot Min MPH for Declutch Hysteresis" 020011 DescSize =0x55 020010 Desc ="DASMHYST - Hysteresis for the 'Dashpot Min MPH for Declutch' (aka DASMPH) parameter." 020020 Units ="mph" 020100 Address =0x8EA3 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x563E 000100 Cat0ID =0x6 020005 Title ="Dashpot Offset" 020011 DescSize =0xA7 020010 Desc ="DASPTO - An offset added to the final dashpot (pre position airflow) value in order to ensure some airflow during tip in or tip out. Typically set around 0.10 lb/min." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x9034 020150 Flags =0x2 020200 Equation =X/4096,TH|0|0|0|0| 020210 DecimalPl =0x6 %%END%% %%CONSTANT%% 000002 UniqueID =0x563F 000100 Cat0ID =0x6 020005 Title ="Dashpot TP" 020011 DescSize =0xCD 020010 Desc ="DELHYS - Used in the calculation of the dashpot (pre position airflow) value. Set equal to the sum of the following parameters;\r\n\r\n'TPS PT Threshold' (aka DELTA)\r\n'TPS PT Threshold Hysteresis' (aka HYSTS)" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x9036 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x530E 000100 Cat0ID =0x11 020005 Title ="DC Correction Factor" 020011 DescSize =0x7 020010 Desc ="DCBIAS" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x8E82 020150 Flags =0x2 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x26B0 000100 Cat0ID =0x11 020005 Title ="Debounce Time Delay" 020011 DescSize =0x7 020010 Desc ="DEBTIM" 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x8E8A 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x51C8 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off CT Min Time Delay" 020011 DescSize =0x10A 020010 Desc ="CTDFSO - The minimum time delay required for deceleration fuel shut off to be permitted when the throttle is closed.\r\nSet to less than the 'Decel Fuel Shut Off Time Delay Extension' (aka CTEDSO) value.\r\nNot used if the 'Decel Fuel Shut Off PT Enable' switch is set." 020020 Units ="secs" 020100 Address =0x9ACE 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x788E 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Fuel Ramp Back Clip" 020011 DescSize =0x4B 020010 Desc ="DMIN - A clip applied to FN379.\r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="???" 020050 SizeInBits =0x10 020100 Address =0x9AD8 020150 Flags =0x2 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3271 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Low Load Timer Run" 020011 DescSize =0x5B 020010 Desc ="DFLDL - The maximum load allowed for the 'Decel Fuel Shut Off Low Load Timer' to count up." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x9ADC 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5DB7 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Low Load Timer Stop" 020011 DescSize =0x5D 020010 Desc ="DFLDH - The minimum load required for the 'Decel Fuel Shut Off Low Load Timer' to be reset." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x9ADE 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x137B 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Low Load Time" 020011 DescSize =0xA 020010 Desc ="DLDFSO - " 020020 Units ="secs" 020100 Address =0x9AE0 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4A83 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Max Load" 020011 DescSize =0x51 020010 Desc ="DFLOD - The maximum load allowed for deceleration fuel shut off to be permitted." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x9AC4 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2FD3 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Max Load Hysteresis" 020011 DescSize =0x42 020010 Desc ="DFLODH - Hysteresis for the 'Decel Fuel Shut Off Max Load' value." 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x9AC6 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x73E5 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min ECT" 020011 DescSize =0x9F 020010 Desc ="DFSECT - The minimum ECT required for deceleration fuel shut off to be permitted prior to the 'Decel Fuel Shut Off Time Delay' (aka AGB) value being exceeded." 020020 Units ="deg F" 020100 Address =0x9AC3 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6278 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min MPH" 020011 DescSize =0x5B 020010 Desc ="DFSVS - The minimum vehicle speed required for deceleration fuel shut off to be permitted." 020020 Units ="mph" 020100 Address =0x9ADA 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x24A5 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min MPH Hysteresis" 020011 DescSize =0x4D 020010 Desc ="DFSVSH - Hysteresis for the 'Decel Fuel Shut Off Min MPH' (aka DFSVS) value." 020020 Units ="mph" 020100 Address =0x9ADB 020200 Equation =X/2,TH|0|0|0|0| 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x49D0 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min PIP To Remain O/L" 020011 DescSize =0x101 020010 Desc ="PIPNUM - After deceleration fuel shut off has finished this is the number of PIPs that must occur in order to stay in open loop mode. This prevents the desired AF ratio from ramping rich until the HEGO transport delay has passed. Set to 1 to calibrate out." 020020 Units ="pips" 020100 Address =0x9AD1 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3E3A 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min RPM" 020011 DescSize =0x66 020010 Desc ="DFSRPM - The minimum rpm above the desired idle rpm at which deceleration fuel shut off is permitted." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9AC8 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6056 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min RPM Hysteresis" 020011 DescSize =0x4E 020010 Desc ="DFSRPH - Hysteresis for the 'Decel Fuel Shut Off Min RPM' (aka DFSRPM) value." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9ACA 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x8F5 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Min Time at PT" 020011 DescSize =0xC4 020010 Desc ="DSFTM - The minimum time at part or wide open throttle required for deceleration fuel shut off to be permitted after the 'Decel Fuel Shut Off CT Min Time Delay' has occurred.\r\n\r\nNeeds confirming." 020020 Units ="secs" 020100 Address =0x9AD0 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x10B 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Neutral Max Time" 020011 DescSize =0x9A 020010 Desc ="DSTM1 - The maximum time that deceleration fuel shut off is permitted during deceleration whilst in neutral.\r\nOnly used if 'Transmission Type' is 2 or 3." 020020 Units ="secs" 020100 Address =0x9ACC 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x186C 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Shift Max Time" 020011 DescSize =0x75 020010 Desc ="DSTM2 - The maximum time that deceleration fuel shut off is permitted during gear shifts on manual gearbox vehicles." 020020 Units ="secs" 020100 Address =0x9ACD 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x656 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Shift Min RPM" 020011 DescSize =0xAE 020010 Desc ="SHFRPM - The minimum rpm above the 'Desired Idle RPM' (aka DSDRPM) required for the deceleration fuel shut off to be permitted during gear shifts on manual gearbox vehicles." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9AD4 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x2F 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Shift Min RPM Hysteresis" 020011 DescSize =0x54 020010 Desc ="SHFHYS - Hysteresis for the 'Decel Fuel Shut Off Shift Min RPM' (aka SHFRPM) value." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x9AD6 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x3E60 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Shift Min TP Hysteresis" 020011 DescSize =0x34 020010 Desc ="TPHYS - \r\n\r\nDoes not appear to be used in this ecu." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x9AD2 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x772 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Time Delay" 020011 DescSize =0xC4 020010 Desc ="AGB - The minimum time that must elapse after exiting crank in order for deceleration fuel shut off to be permitted when the ECT is less than the 'Decel Fuel Shut Off Min ECT' (aka DFSECT) value." 020020 Units ="secs" 020100 Address =0x8FE3 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1D75 000100 Cat0ID =0x1 020005 Title ="Decel Fuel Shut Off Time Extension" 020011 DescSize =0x13E 020010 Desc ="CTEDSO - Used to keep deceleration fuel shut off continuing during long decelerations (such as lengthy descents) even if short tip in/tip out events occur.\r\nSet to greater than the 'Decel Fuel Shut Off CT Min Time Delay' (aka CTDFSO) value.\r\nNot used if the 'Decel Fuel Shut Off PT Enable' (aka PTDFSW) switch is set." 020020 Units ="secs" 020100 Address =0x9ACF 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3998 000100 Cat0ID =0xB 020005 Title ="Default ACT" 020011 DescSize =0x6C 020010 Desc ="ACTFMM - Default value used for ACT when the ACT sensor has failed and (other conditions to be determined)." 020020 Units ="deg F" 020100 Address =0x9427 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x182E 000100 Cat0ID =0x5 020005 Title ="Default BAP" 020011 DescSize =0x4E 020010 Desc ="KONBP - Default barometric pressure value used when no BAP sensor is fitted.." 020020 Units ="in Hg" 020100 Address =0x947C 020200 Equation =X/8,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6F57 000100 Cat0ID =0xB 020005 Title ="Default BAP for Sensor Fail" 020011 DescSize =0x50 020010 Desc ="BAPFMM - Default barometric pressure value used when the BAP sensor has failed." 020020 Units ="in Hg" 020100 Address =0x942E 020200 Equation =X/8,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0xFE6 000100 Cat0ID =0xB 020005 Title ="Default ECT" 020011 DescSize =0x6C 020010 Desc ="ECTFMM - Default value used for ECT when the ECT sensor has failed and (other conditions to be determined)." 020020 Units ="deg F" 020100 Address =0x9428 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x49DD 000100 Cat0ID =0xB 020005 Title ="Default Desired Idle RPM" 020011 DescSize =0x4E 020010 Desc ="FMMDSD - Default desired idle rpm when both TPS and MAF failed flags are set." 020020 Units ="rpm" 020100 Address =0x9426 020200 Equation =X*16,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5FF5 000100 Cat0ID =0xB 020005 Title ="Default ISC Dutycycle" 020011 DescSize =0x49 020010 Desc ="FMMISC - Default ISC dutycyle when both TPS and MAF failed flags are set" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x9424 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1790 000100 Cat0ID =0xB 020005 Title ="Default TP" 020011 DescSize =0xA6 020010 Desc ="FMCTTP - Added to closed throttle value to give a default throttle value if either the TPS has failed, is less than 'TPS Min' value or greater than 'TPS Max' value." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x942A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xFE9 000100 Cat0ID =0x1 020005 Title ="Desired A/F Ratio Max" 020011 DescSize =0x59 020010 Desc ="LAMMAX - The desired A/F ratio is clipped to this limit during closed loop fuel control." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x9AA2 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x809 000100 Cat0ID =0x1 020005 Title ="Desired A/F Ratio Min" 020011 DescSize =0x59 020010 Desc ="LAMMIN - The desired A/F ratio is clipped to this limit during closed loop fuel control." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x9AA4 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5A85 000100 Cat0ID =0xC 020005 Title ="Desired EGR Valve Position Time Constant" 020011 DescSize =0xEF 020010 Desc ="TCDLOP - The time constant for the rolling average calculation of the 'Desired EGR Valve Position' (aka DELOPT) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97E8 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x42DA 000100 Cat0ID =0x9 020005 Title ="Desired Idle RPM Self Test Time Constant" 020011 DescSize =0x18B 020010 Desc ="VTCDSN - The time constant for the rolling average calculation of the 'Desired Idle RPM' (aka DSDRPM) value during self test.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it.\r\n\r\nSetting to zero will result in the 'Desired Idle RPM Time Constant' (aka TCDESN) parameter being used in lieu of this parameter during self test." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x8EEA 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xBA2 000100 Cat0ID =0x6 020005 Title ="Desired Idle RPM Time Constant" 020011 DescSize =0xE5 020010 Desc ="TCDESN - The time constant for the rolling average calculation of the 'Desired Idle RPM' (aka DSDRPM) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97E6 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6D8E 000100 Cat0ID =0x1 020005 Title ="Desired Rich Correction" 020011 DescSize =0x81 020010 Desc ="LMBJMP - When exiting the Filtered Idle Airmass Region this value is subtracted from the desired AF ratio to richen the mixture." 020020 Units ="A/F ratio" 020050 SizeInBits =0x10 020100 Address =0x9AF2 020150 Flags =0x2 020200 Equation =X/32768*14.64,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7C3D 000100 Cat0ID =0x7 020005 Title ="Disable ISC" 020011 DescSize =0xE3 020010 Desc ="Z_ISCSW - Normally this is set to \"3A\", change to \"00\" to set the ISC valve dutycycle to 0% when determining the 'Throttle Body Air Flow' (aka ITHBMA) parameter value.\r\n\r\nWARNING: Do not use any values other than one of these." 020020 Units ="" 020100 Address =0x5E4D 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x3 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x197F 000100 Cat0ID =0x2 020005 Title ="Dwell Switch Point" 020011 DescSize =0x41 020010 Desc ="DWLTSW - Switch point for the change of maximum permitted dwell." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x945C 020150 Flags =0x2 020200 Equation =X/65536,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7D4E 000100 Cat0ID =0x7 020005 Title ="Dwell Time Table Select Temperature" 020011 DescSize =0xD4 020010 Desc ="DWLTBP - The estimated coil temperature value used to determine which coil dwell time table is to be used. The tables are:\r\n\r\n'Dwell Time High Temperature' (aka FN160B)\r\n'Dwell Time Low Temperature' (aka FN160A)" 020020 Units ="deg F" 020100 Address =0x945B 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x30FD 000100 Cat0ID =0x2 020005 Title ="Dwell Turn On Time Low RPM Clip" 020011 DescSize =0x7 020010 Desc ="MINDLA" 020020 Units ="% of PIP period" 020050 SizeInBits =0x10 020100 Address =0x9456 020150 Flags =0x2 020200 Equation =X/655.36,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x7F70 000100 Cat0ID =0x2 020005 Title ="Dwell Turn On Time High RPM Clip" 020011 DescSize =0x7 020010 Desc ="MINDLB" 020020 Units ="% of PIP period" 020050 SizeInBits =0x10 020100 Address =0x9458 020150 Flags =0x2 020200 Equation =X/655.36,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1379 000100 Cat0ID =0x9 020005 Title ="ECT KOEO Max" 020011 DescSize =0x7 020010 Desc ="VIECT2" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F52 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5622 000100 Cat0ID =0x9 020005 Title ="ECT KOEO Min" 020011 DescSize =0x7 020010 Desc ="VIECT1" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F50 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3FEB 000100 Cat0ID =0x9 020005 Title ="ECT KOER Max" 020011 DescSize =0x7 020010 Desc ="VIECT4" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F56 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x20B8 000100 Cat0ID =0x9 020005 Title ="ECT KOER Min" 020011 DescSize =0x7 020010 Desc ="VIECT3" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F54 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5DC4 000100 Cat0ID =0x4 020005 Title ="ECT Max" 020011 DescSize =0x54 020010 Desc ="ECTMAX - Value at which the eec considers that the sensor has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8EDA 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x356A 000100 Cat0ID =0xA 020005 Title ="ECT Max at Start for Warm Up Flag" 020011 DescSize =0xC9 020010 Desc ="VECT5 - The maximum coolant temperature at start up permitted for the KAM Warm Up counter to be updated. The temperature then needs to increase beyond the 'ECT Min for Warm Up Flag' (aka VECT3) value." 020020 Units ="deg F" 020100 Address =0x8EC6 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x32F9 000100 Cat0ID =0x4 020005 Title ="ECT Min" 020011 DescSize =0x54 020010 Desc ="ECTMIN - Value at which the eec considers that the sensor has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8ED8 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6FE2 000100 Cat0ID =0xA 020005 Title ="ECT Min for Warm Up Flag" 020011 DescSize =0xCB 020010 Desc ="VECT3 - The minimum coolant temperature required for the KAM Warm Up counter to be updated. The temperature at start also needs to be less than the 'ECT Max at Start for Warm Up Flag' (aka VECT5) value." 020020 Units ="deg F" 020100 Address =0x8F58 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E9B 000100 Cat0ID =0x3 020005 Title ="ECT Time Constant" 020011 DescSize =0xD4 020010 Desc ="TCECT - The time constant for the rolling average calculation of the 'ECT' (aka ECT) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97EC 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x8EC 000100 Cat0ID =0xC 020005 Title ="EGR Actual Percent Time Constant" 020011 DescSize =0xE7 020010 Desc ="TCEACT - The time constant for the rolling average calculation of the 'EGR Actual Percent' (aka EGRACT) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97EE 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7DE1 000100 Cat0ID =0xC 020005 Title ="EGR Cold Start Delay #1" 020011 DescSize =0xA 020010 Desc ="EGRTD1 - " 020020 Units ="secs" 020100 Address =0x97CA 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1093 000100 Cat0ID =0x9 020005 Title ="EGR Continuous Flow Test Max Load " 020011 DescSize =0x9 020010 Desc ="VEGRLOAD" 020020 Units ="load" 020050 SizeInBits =0x10 020100 Address =0x8F08 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x1959 000100 Cat0ID =0xC 020005 Title ="EGR Cold Start Delay #2" 020011 DescSize =0xA 020010 Desc ="EGRTD4 - " 020020 Units ="secs" 020100 Address =0x97CB 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2ED6 000100 Cat0ID =0x9 020005 Title ="EGR Cruise Test Dutycycle" 020011 DescSize =0x7 020010 Desc ="VCRTDC" 020020 Units ="%" 020100 Address =0x8F03 020200 Equation =X/1.28,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x76FF 000100 Cat0ID =0x9 020005 Title ="EGR Cruise Test Time" 020011 DescSize =0x7 020010 Desc ="VECTMR" 020020 Units ="secs" 020100 Address =0x8F02 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1E7F 000100 Cat0ID =0xC 020005 Title ="EGR Deadband Value for EVP" 020011 DescSize =0x7 020010 Desc ="EGRDED" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x97D0 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6EE1 000100 Cat0ID =0xC 020005 Title ="EGR Desired Downstream Pressure Time Constant" 020011 DescSize =0xF1 020010 Desc ="TCDP - The time constant for the rolling average calculation of the 'EGR Desired Downstream Pressure' (aka DESDP) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97EA 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4370 000100 Cat0ID =0xC 020005 Title ="EGR Dutycycle for Valve to Open" 020011 DescSize =0x6 020010 Desc ="DCOFF" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x97CE 020150 Flags =0x2 020200 Equation =X/327.68,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4610 000100 Cat0ID =0xC 020005 Title ="EGR Hot Start Delay" 020011 DescSize =0xA 020010 Desc ="EGRTD3 - " 020020 Units ="secs" 020100 Address =0x97C7 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7F4D 000100 Cat0ID =0xC 020005 Title ="EGR Mass Flow Minimum" 020011 DescSize =0x93 020010 Desc ="MINDES - The minimum desired EGR mass flow allowed in order to avoid EGR operation in the low flow non linear region of the EGR transfer function." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x97DE 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4FBC 000100 Cat0ID =0xC 020005 Title ="EGR Mass Flow Minimum Hysteresis" 020011 DescSize =0x4C 020010 Desc ="DESHYS - Hysteresis for the 'EGR Mass Flow Minimum' (aka MINDES) parameter." 020020 Units ="lb/min" 020050 SizeInBits =0x10 020100 Address =0x97E0 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4C3C 000100 Cat0ID =0xC 020005 Title ="EGR Multiplier" 020011 DescSize =0x5 020010 Desc ="X - " 020020 Units ="multiplier" 020100 Address =0x97CD 020200 Equation =X/128,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5DD1 000100 Cat0ID =0xC 020005 Title ="EGR PT Adder" 020011 DescSize =0x5 020010 Desc ="KPEI" 020020 Units ="%" 020100 Address =0x97CC 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5E02 000100 Cat0ID =0xC 020005 Title ="EGR Ramp In Delay" 020011 DescSize =0x7 020010 Desc ="EGRMPT" 020020 Units ="secs" 020100 Address =0x97D2 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x40F8 000100 Cat0ID =0x9 020005 Title ="EGR Test Dutycycle Maximum" 020011 DescSize =0x7 020010 Desc ="VDCMAX" 020020 Units ="%" 020100 Address =0x8F06 020200 Equation =X/1.28,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x55BA 000100 Cat0ID =0x9 020005 Title ="EGR Test Dutycycle Rate" 020011 DescSize =0x7 020010 Desc ="VEGRAT" 020020 Units ="% per sec" 020100 Address =0x8F04 020200 Equation =X/1.28,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x5CCB 000100 Cat0ID =0x9 020005 Title ="EGR Test Dutycycle Minimum" 020011 DescSize =0x7 020010 Desc ="VDCMIN" 020020 Units ="%" 020100 Address =0x8F05 020200 Equation =X/1.28,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4127 000100 Cat0ID =0xC 020005 Title ="EGR Time Constant" 020011 DescSize =0xD7 020010 Desc ="TCEGR - The time constant for the rolling average calculation of the 'EGR' (aka EGRBAR) value.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x9808 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1B40 000100 Cat0ID =0x9 020005 Title ="EGR Test Time Wait" 020011 DescSize =0x7 020010 Desc ="VEITMR" 020020 Units ="secs" 020100 Address =0x8F16 020200 Equation =X/8,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E06 000100 Cat0ID =0xC 020005 Title ="EGR Type" 020011 DescSize =0x27 020010 Desc ="PFEHP - 0 = sonic, 1 = PFE, 2 = no egr" 020020 Units ="" 020100 Address =0x97D9 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x77BC 000100 Cat0ID =0xC 020005 Title ="EGR Warm Start Delay #1" 020011 DescSize =0xA 020010 Desc ="EGRTD2 - " 020020 Units ="secs" 020100 Address =0x97C8 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x29A 000100 Cat0ID =0xC 020005 Title ="EGR Warm Start Delay #2" 020011 DescSize =0xA 020010 Desc ="EGRTD5 - " 020020 Units ="secs" 020100 Address =0x97C9 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5DA2 000100 Cat0ID =0x7 020005 Title ="Engine Displacement" 020011 DescSize =0xA1 020010 Desc ="SARCHG - If altered the following parameters will need adjustment too;\r\n\r\n'Manifold Fast Fill Constant' (aka FKARC1)\r\n'Manifold Slow Fill Constant' (aka FKARCH)" 020020 Units ="Cubic In." 020050 SizeInBits =0x10 020100 Address =0x901A 020150 Flags =0x2 020200 Equation =X*0.0430981,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x568F 000100 Cat0ID =0x5 020005 Title ="Engine Warm ECT" 020011 DescSize =0x4F 020010 Desc ="TEMPFB - The minimum temperature at which the engine is considered to be warm." 020020 Units ="deg F" 020100 Address =0x9E60 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2505 000100 Cat0ID =0xC 020005 Title ="EPT at Idle Back Pressure" 020011 DescSize =0x62 020010 Desc ="IDLDEL - Checked during the key on 'EPT at Idle' (aka EPTZER) update routine.\r\n\r\nTo be confirmed." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x947E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E37 000100 Cat0ID =0xC 020005 Title ="EPT at Idle Min ECT" 020011 DescSize =0x53 020010 Desc ="CTEHI - The minimum ECT for the 'EPT at Idle' (aka EPTZER) value to be calculated." 020020 Units ="deg F" 020100 Address =0x97DC 020150 Flags =0x1 020200 Equation =X*2,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x34BC 000100 Cat0ID =0xC 020005 Title ="EPT at Idle RPM Hysteresis" 020011 DescSize =0x94 020010 Desc ="IERPMH - Hysteresis value added to 'Desired Idle RPM' value. If the rpm exceeds this resultant value then the 'EPT at Idle' calculation is skipped." 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x97DA 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x4EC4 000100 Cat0ID =0x9 020005 Title ="EPT Continuous Test Max" 020011 DescSize =0x7 020010 Desc ="VEPTIH" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F9C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x198C 000100 Cat0ID =0x9 020005 Title ="EPT Continuous Test Min" 020011 DescSize =0x7 020010 Desc ="VEPTIL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F9A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x773F 000100 Cat0ID =0x9 020005 Title ="EPT Cruise Test Min" 020011 DescSize =0x7 020010 Desc ="VEPTCL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8FA0 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4514 000100 Cat0ID =0x9 020005 Title ="EPT KOEO Max" 020011 DescSize =0x7 020010 Desc ="VEPTHL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F94 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x1B88 000100 Cat0ID =0x9 020005 Title ="EPT KOEO Min" 020011 DescSize =0x7 020010 Desc ="VEPTLL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F92 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x592F 000100 Cat0ID =0x9 020005 Title ="EPT KOER Max" 020011 DescSize =0x7 020010 Desc ="VEPTRH" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F98 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5B53 000100 Cat0ID =0x9 020005 Title ="EPT KOER Min" 020011 DescSize =0x7 020010 Desc ="VEPTRL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F96 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6A24 000100 Cat0ID =0x9 020005 Title ="EPT KOER Min Change" 020011 DescSize =0x7 020010 Desc ="VEPTDL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F9E 020150 Flags =0x3 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x7952 000100 Cat0ID =0x4 020005 Title ="EPT Max" 020011 DescSize =0x69 020010 Desc ="EPTMAX - Value at which the eec considers that the exhaust pressure transducer has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F90 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x4FA4 000100 Cat0ID =0x4 020005 Title ="EPT Min" 020011 DescSize =0x69 020010 Desc ="EPTMIN - Value at which the eec considers that the exhaust pressure transducer has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F8E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x59C8 000100 Cat0ID =0x9 020005 Title ="EPT Test Time Constant" 020011 DescSize =0xE9 020010 Desc ="VTCEPT - The time constant for the rolling average calculation of the 'EPT' (aka EPTBAR) value during self test.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x8FA4 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xF53 000100 Cat0ID =0xC 020005 Title ="EPT Time Constant" 020011 DescSize =0xF7 020010 Desc ="TCEPT - The time constant for the rolling average calculation of the 'EPT' (aka EPTBAR) and 'EPT at Idle' (aka EPTZER) values.\r\n\r\nLarger time constant values increase the time lag of the value being updated but reduce unwanted transients from it." 020020 Units ="secs" 020050 SizeInBits =0x10 020100 Address =0x97F0 020150 Flags =0x2 020200 Equation =X/1024,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5E03 000100 Cat0ID =0xC 020005 Title ="EPT Transfer" 020011 DescSize =0x7 020010 Desc ="XFREPT" 020020 Units ="in H2O/counts" 020050 SizeInBits =0x10 020100 Address =0x97D4 020150 Flags =0x3 020200 Equation =X/131072,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0xBA1 000100 Cat0ID =0xC 020005 Title ="EPT Transfer Reciprocol" 020011 DescSize =0x7 020010 Desc ="IXFRPR" 020020 Units ="counts/in H2O" 020050 SizeInBits =0x10 020100 Address =0x97D6 020150 Flags =0x3 020200 Equation =X/131072,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5574 000100 Cat0ID =0x12 020005 Title ="Equilibrium Fuel Transfer Constant Multiplier" 020011 DescSize =0x6B 020010 Desc ="MTEFTC - A multiplier of the result of the 'Equilibrium Fuel Transfer Constant' (aka FN1322) table lookup." 020020 Units ="multiplier" 020100 Address =0x9012 020200 Equation =X/32,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5573 000100 Cat0ID =0x12 020005 Title ="Equilibrium Intake Surface Fuel Multiplier" 020011 DescSize =0x68 020010 Desc ="MTEISF - A multiplier of the result of the 'Equilibrium Intake Surface Fuel' (aka FN1321) table lookup." 020020 Units ="multiplier" 020100 Address =0x9011 020200 Equation =X/32,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2526 000100 Cat0ID =0x9 020005 Title ="Error 14 Threshold (PIP fault)" 020011 DescSize =0x1C 020010 Desc ="C14LVL - PIP signal erratic" 020020 Units ="" 020100 Address =0x8F1B 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4AF8 000100 Cat0ID =0x9 020005 Title ="Error 14 Up Count (PIP fault)" 020011 DescSize =0x1B 020010 Desc ="C14UP - PIP signal erratic" 020020 Units ="" 020100 Address =0x8F31 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x214C 000100 Cat0ID =0x9 020005 Title ="Error 22 Threshold (BP fault)" 020011 DescSize =0x20 020010 Desc ="C22LVL - BP sensor out of range" 020020 Units ="" 020100 Address =0x8F1C 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x26A 000100 Cat0ID =0x9 020005 Title ="Error 22 Up Count (BP fault)" 020011 DescSize =0x21 020010 Desc ="C22UP - BAP sensor out of range." 020020 Units ="" 020100 Address =0x8F32 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7DD6 000100 Cat0ID =0x9 020005 Title ="Error 29 Threshold (VSS fault)" 020011 DescSize =0x13 020010 Desc ="C29LVL - VSS fault" 020020 Units ="" 020100 Address =0x8F1D 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7DE8 000100 Cat0ID =0x9 020005 Title ="Error 29 Up Count (VSS fault)" 020011 DescSize =0x13 020010 Desc ="\"C22UP - VSS fault" 020020 Units ="" 020100 Address =0x8F33 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x51CE 000100 Cat0ID =0x9 020005 Title ="Error 31 Threshold (EVP fault)" 020011 DescSize =0x39 020010 Desc ="C31LVL - Evaporative canister purge solenoid range error" 020020 Units ="" 020100 Address =0x8F1E 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6654 000100 Cat0ID =0x9 020005 Title ="Error 31 Up Count (EVP fault)" 020011 DescSize =0x38 020010 Desc ="C31UP - Evaporative canister purge solenoid range error" 020020 Units ="" 020100 Address =0x8F34 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x20BB 000100 Cat0ID =0x9 020005 Title ="Error 32 Threshold (EVP limit)" 020011 DescSize =0x48 020010 Desc ="C32LVL - Evaporative canister purge solenoid not responding during test" 020020 Units ="" 020100 Address =0x8F1F 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4CC0 000100 Cat0ID =0x9 020005 Title ="Error 32 Up Count (EVP limit)" 020011 DescSize =0x47 020010 Desc ="C32UP - Evaporative canister purge solenoid not responding during test" 020020 Units ="" 020100 Address =0x8F35 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x740C 000100 Cat0ID =0x9 020005 Title ="Error 33 Threshold (EGR flow)" 020011 DescSize =0x1A 020010 Desc ="C33LVL - EGR did not flow" 020020 Units ="" 020100 Address =0x8F20 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x40E8 000100 Cat0ID =0x9 020005 Title ="Error 33 Up Count (EGR flow)" 020011 DescSize =0x1A 020010 Desc ="C33UP - EGR did not flow." 020020 Units ="" 020100 Address =0x8F36 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6467 000100 Cat0ID =0x9 020005 Title ="Error 34 Threshold (EGR limit)" 020011 DescSize =0x19 020010 Desc ="C34LVL - EGR range error" 020020 Units ="" 020100 Address =0x8F21 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1FF7 000100 Cat0ID =0x9 020005 Title ="Error 34 Up Count (EGR limit)" 020011 DescSize =0x19 020010 Desc ="C34UP - EGR range error." 020020 Units ="" 020100 Address =0x8F37 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x55AE 000100 Cat0ID =0x9 020005 Title ="Error 35 Threshold (EVP high)" 020011 DescSize =0x18 020010 Desc ="C35LVL - EVP input high" 020020 Units ="" 020100 Address =0x8F22 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x71DC 000100 Cat0ID =0x9 020005 Title ="Error 35 Up Count (EVP high)" 020011 DescSize =0x17 020010 Desc ="C35UP - EVP input high" 020020 Units ="" 020100 Address =0x8F38 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x85F 000100 Cat0ID =0x9 020005 Title ="Error 41 Threshold (right HEGO switching)" 020011 DescSize =0x27 020010 Desc ="C41LVL - Lack of right HEGO switching." 020020 Units ="" 020100 Address =0x8F23 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x5CB5 000100 Cat0ID =0x9 020005 Title ="Error 41 Up Count (right HEGO switching)" 020011 DescSize =0x26 020010 Desc ="C41UP - Lack of right HEGO switching." 020020 Units ="" 020100 Address =0x8F39 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6ED6 000100 Cat0ID =0x9 020005 Title ="Error 51 Threshold (ECT open circuit)" 020011 DescSize =0x1A 020010 Desc ="C51LVL - ECT open circuit" 020020 Units ="" 020100 Address =0x8F24 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x290D 000100 Cat0ID =0x9 020005 Title ="Error 51 Up Count (ECT open circuit)" 020011 DescSize =0x19 020010 Desc ="C51UP - ECT open circuit" 020020 Units ="" 020100 Address =0x8F3A 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1EBF 000100 Cat0ID =0x9 020005 Title ="Error 53 Threshold (TPS open circuit)" 020011 DescSize =0x1A 020010 Desc ="C53LVL - TPS open circuit" 020020 Units ="" 020100 Address =0x8F25 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2800 000100 Cat0ID =0x9 020005 Title ="Error 53 Up Count (TPS open circuit)" 020011 DescSize =0x19 020010 Desc ="C53UP - TPS open circuit" 020020 Units ="" 020100 Address =0x8F3B 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xA08 000100 Cat0ID =0x9 020005 Title ="Error 54 Threshold (ACT open circuit)" 020011 DescSize =0x1A 020010 Desc ="C54LVL - ACT open circuit" 020020 Units ="" 020100 Address =0x8F26 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7FF4 000100 Cat0ID =0x9 020005 Title ="Error 54 Up Count (ACT open circuit)" 020011 DescSize =0x19 020010 Desc ="C54UP - ACT open circuit" 020020 Units ="" 020100 Address =0x8F3C 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4EA0 000100 Cat0ID =0x9 020005 Title ="Error 56 Threshold (MAF open circuit)" 020011 DescSize =0x1A 020010 Desc ="C56LVL - MAF open circuit" 020020 Units ="" 020100 Address =0x8F27 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x63F7 000100 Cat0ID =0x9 020005 Title ="Error 56 Up Count (MAF open circuit)" 020011 DescSize =0x19 020010 Desc ="C56UP - MAF open circuit" 020020 Units ="" 020100 Address =0x8F3D 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2324 000100 Cat0ID =0x9 020005 Title ="Error 61 Threshold (ECT short circuit)" 020011 DescSize =0x1B 020010 Desc ="C61LVL - ECT short circuit" 020020 Units ="" 020100 Address =0x8F28 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x2894 000100 Cat0ID =0x9 020005 Title ="Error 61 Up Count (ECT short circuit)" 020011 DescSize =0x1A 020010 Desc ="C61UP - ECT short circuit" 020020 Units ="" 020100 Address =0x8F3E 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x580F 000100 Cat0ID =0x9 020005 Title ="Error 63 Threshold (TPS short circuit)" 020011 DescSize =0x1B 020010 Desc ="C63LVL - TPS short circuit" 020020 Units ="" 020100 Address =0x8F29 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6603 000100 Cat0ID =0x9 020005 Title ="Error 63 Up Count (TPS short circuit)" 020011 DescSize =0x1A 020010 Desc ="C63UP - TPS short circuit" 020020 Units ="" 020100 Address =0x8F3F 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x1BD3 000100 Cat0ID =0x9 020005 Title ="Error 64 Threshold (ACT short circuit)" 020011 DescSize =0x1B 020010 Desc ="C64LVL - ACT short circuit" 020020 Units ="" 020100 Address =0x8F2A 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xEB1 000100 Cat0ID =0x9 020005 Title ="Error 64 Up Count (ACT short circuit)" 020011 DescSize =0x1A 020010 Desc ="C64UP - ACT short circuit" 020020 Units ="" 020100 Address =0x8F40 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x53AE 000100 Cat0ID =0x9 020005 Title ="Error 66 Threshold (MAF short circuit)" 020011 DescSize =0x1B 020010 Desc ="C66LVL - MAF short circuit" 020020 Units ="" 020100 Address =0x8F2B 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x679D 000100 Cat0ID =0x9 020005 Title ="Error 66 Up Count (MAF short circuit)" 020011 DescSize =0x1A 020010 Desc ="C66UP - MAF short circuit" 020020 Units ="" 020100 Address =0x8F41 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x120C 000100 Cat0ID =0x9 020005 Title ="Error 87 Threshold (fuel pump fault)" 020011 DescSize =0x21 020010 Desc ="C87LVL - Fuel pump circuit fault" 020020 Units ="" 020100 Address =0x8F2C 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0xA9D 000100 Cat0ID =0x9 020005 Title ="Error 87 Up Count (fuel pump fault)" 020011 DescSize =0x20 020010 Desc ="C87UP - Fuel pump circuit fault" 020020 Units ="" 020100 Address =0x8F42 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x59E5 000100 Cat0ID =0x9 020005 Title ="Error 91 Threshold (left HEGO switching)" 020011 DescSize =0x26 020010 Desc ="C91LVL - Lack of left HEGO switching." 020020 Units ="" 020100 Address =0x8F2D 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4428 000100 Cat0ID =0x9 020005 Title ="Error 91 Up Count (left HEGO switching)" 020011 DescSize =0x25 020010 Desc ="C91UP - Lack of left HEGO switching." 020020 Units ="" 020100 Address =0x8F43 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x4D50 000100 Cat0ID =0x9 020005 Title ="Error 95 Threshold (fuel pump open circuit)" 020011 DescSize =0x3A 020010 Desc ="C95LVL - Fuel pump open circuit, bad ground or always on." 020020 Units ="" 020100 Address =0x8F2E 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x7439 000100 Cat0ID =0x9 020005 Title ="Error 95 Up Count (fuel pump open circuit)" 020011 DescSize =0x39 020010 Desc ="C95UP - Fuel pump open circuit, bad ground or always on." 020020 Units ="" 020100 Address =0x8F44 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x6865 000100 Cat0ID =0x9 020005 Title ="Error 96 Threshold (fuel pump monitor)" 020011 DescSize =0x33 020010 Desc ="C96LVL - Fuel pump monitor circuit shows no power." 020020 Units ="" 020100 Address =0x8F2F 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x3292 000100 Cat0ID =0x9 020005 Title ="Error 96 Up Count (fuel pump monitor)" 020011 DescSize =0x32 020010 Desc ="C96UP - Fuel pump monitor circuit shows no power." 020020 Units ="" 020100 Address =0x8F45 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x336C 000100 Cat0ID =0x9 020005 Title ="EVP Cruise Test Limit" 020011 DescSize =0x7 020010 Desc ="VEVPCL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F14 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2C9 000100 Cat0ID =0x9 020005 Title ="EVP Test Lower Limit" 020011 DescSize =0x7 020010 Desc ="VEVPLL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F0E 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x5F54 000100 Cat0ID =0x9 020005 Title ="EVP Test Minimum Change" 020011 DescSize =0x7 020010 Desc ="VEVPDL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F12 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x697A 000100 Cat0ID =0x9 020005 Title ="EVP Test Upper Limit" 020011 DescSize =0x7 020010 Desc ="VEVPHL" 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F10 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x3841 000100 Cat0ID =0x9 020005 Title ="EVR Open Circuit Check" 020011 DescSize =0xA 020010 Desc ="OCCDT4 - " 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F82 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x2B14 000100 Cat0ID =0x4 020005 Title ="EVP Max" 020011 DescSize =0x68 020010 Desc ="EVPMAX - Value at which the eec considers that the evaporative canister purge has failed open circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F0C 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x62DE 000100 Cat0ID =0x9 020005 Title ="EPT Test Max Idle RPM" 020011 DescSize =0x3 020010 Desc ="VN" 020020 Units ="rpm" 020050 SizeInBits =0x10 020100 Address =0x8FA2 020150 Flags =0x2 020200 Equation =X/4,TH|0|0|0|0| %%END%% %%CONSTANT%% 000002 UniqueID =0x6D1F 000100 Cat0ID =0x4 020005 Title ="EVP Min" 020011 DescSize =0x71 020010 Desc ="EVPMIN - Value at which the eec considers that the evaporative canister purge solenoid has failed short circuit." 020020 Units ="volts" 020050 SizeInBits =0x10 020100 Address =0x8F0A 020150 Flags =0x2 020200 Equation =X/12800,TH|0|0|0|0| 020210 DecimalPl =0x3 %%END%% %%CONSTANT%% 000002 UniqueID =0x6A18 000100 Cat0ID =0x9 020005 Title ="Failure Mode Hysteresis" 020011 DescSize =0x50 020010 Desc ="FILHYS - Hysteresis value for the 'Error ** Threshold' (aka C**LVL) parameters." 020020 Units ="" 020100 Address =0x8F59 020200 Equation =X,TH|0|0|0|0| 020205 OutType =0x2 020210 DecimalPl =0x1 %%END%% %%CONSTANT%% 000002 UniqueID =0x69F6 000100 Cat0ID =0x6 020005 Title ="FAM Deadband" 020011 DescSize =0x7 020010 Desc ="FAMLIM" 020020 Units ="%" 020050 SizeInBits =0x10 020100 Address =0x9054 020150 Fl